SOFTWARE  

SETUP 

To install the software on the your PC: 

1.

 

Insert the AD9956/PCB evaluation software CD-ROM into 
the CD-ROM drive.  

2.

 

Use Windows Explorer to navigate to the CD-ROM drive.  

3.

 

The folders at the root level are labeled 

Datashts

DDS_Tu

t, 

Instruct

Layout

Schematic

, and 

Software

The 

Datashts

 folder contains the data sheet for the 

AD9956. 

DDS_Tut

 contains the DDS tutorial. 

Instruct

 

contains the evaluation board software and hardware 
instructions (this document). 

Layout

 contains the PCB 

layout files for the evaluation board. 

Software

 contains the 

setup.exe

 file for the evaluation software and the file 

install.pdf

.  

4.

 

Read 

install.pdf

 completely and then follow the instruc-

tions in this file to install the software on your PC. 

RUNNING AND USING THE SOFTWARE 

To launch the evaluation software: 

1.

 

Find the executable, 

AD9956v.exe

, in the following folder: 

c:\Program Files\ADI\AD9956 Evaluation Software 

2.

 

Double-click the icon to launch the evaluation software.  A 
status window similar to Figure 2 appears  in the center of 
the 

AD9956 Evaluation Software

 dialog box as progress is 

made in loading the evaluation software (a black window 
with green text). If the software loads successfully, the text 
remains green and the “software up and running” message 
is displayed. If the loading fails, the text turns red, and a 
message describing the failure is displayed.  

Three dialog boxes are automatically loaded: 

Control

Profile

and 

DUT Signals

. You can load other dialog boxes from the 

View

 menu. You can also program the registers of the device 

directly from the 

Debug Window

, which you can access from 

the 

View

 menu.  

At startup, the software searches for the presence of a function-
ing AD9956 evaluation board. If it detects the evaluation board, 
a green splash screen appears, as shown in Figure 2. If it fails to 
detect a working part, a red error message is displayed. 

05278-002

 

Figure 2. AD9956/PCB Evaluation Board Software Status Message upon Successful Load 

 

Содержание AD9953YSVZ

Страница 1: ...781 326 8703 2005 Analog Devices Inc All rights reserved EVALUATION BOARD FUNCTIONAL BLOCK DIAGRAM M DDS R VCO N LPF AD9956 LPF VCO AND LOOP FILTER ONLY POPULATED ON AD9956 VCO PCB THESE SOCKETS LEFT...

Страница 2: ...nning and Using the Software 4 Control Dialog Box 5 Profile Dialog Box 6 Clock Driver Control Phase Frequency Detector Charge Pump Dialog Box 7 DUT Signals Dialog Box 8 DUT I O Dialog Box 8 Debug Wind...

Страница 3: ...ind of application the external signal should be applied to the DUT REF IN connector J2 This leads to the AD9956 Pins PLLREF PLLREF the reference input of the AD9956 s phase frequency detector See the...

Страница 4: ...Program Files ADI AD9956 Evaluation Software 2 Double click the icon to launch the evaluation software A status window similar to Figure 2 appears in the center of the AD9956 Evaluation Software dial...

Страница 5: ...raw undivided REFCLK is used as the internal system clock when this box is checked Do not select this box if the REFCLK input is greater than 400 MHz Output Waveform In the Output Waveform box select...

Страница 6: ...output The PLL lock detect enable bit in the Charge Pump dialog box enables a PLL lock monitoring function either through the PLL_LOCK_DETECT pin externally or by setting a flag in the control regist...

Страница 7: ...ntire charge pump A delay occurs when coming out of this power down to reestablish the correct charge pump current Select Charge Pump Quick Powerdown to power down the phase detector logic while keepi...

Страница 8: ...end an I O update to the device s every time you click LOAD default on If you want a device to wait for a manually sent I O update signal clear the corresponding check box DUT I O DIALOG BOX This dial...

Страница 9: ...The Debug Window shown in Figure 9 lets you directly write to any of the internal registers and subsequently read them back You can also directly toggle the states of any external inputs such as PS0...

Страница 10: ...harge sensitive device Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection Although this product features proprietary ES...

Страница 11: ...AD9956 PCB Rev 0 Page 11 of 12 NOTES...

Страница 12: ...AD9956 PCB Rev 0 Page 12 of 12 NOTES 2005 Analog Devices Inc All rights reserved Trademarks and registered trademarks are the property of their respective owners EB05278 0 1 05 0...

Отзывы: