September 2012
L010155
35
A - Acceleration/Deceleration
Format:
A[value]
Description: This command sets the acceleration profile which is an integer value between
100 and 9,999,999. The higher the value, the faster the motor acceleration.
Range:
100 - 9,999,999
B - Base Speed
Format:
B[value]
Description: This command sets the base (start) speed for motion. This value must be
set before motion begins and be less then the maximum speed and fast jog speed.
Range:
1 - 5000
C - Number of Steps Between Outputs During Output on the Fly
Format:
C[value]
Description: This command sets the number of steps between when output 1 turns on
during an output on the fly move. If only one output turn on is needed, set this value to 0.
This command is used in conjunction with the output on the fly enabled “(“ command.
Range:
0 - 65535
D - 1
st
Output on the Fly Position
Format:
D[value]
Description: This command sets the position at which output 1 will turn on during an output
on the fly move. This command is used in conjunction with the output on the fly enabled “(“
command.
Range:
0 - 65535
EA - Encoder Autocorrect Enabled
Format:
EA[0 or 1]
Description: This command will either enable or disable the encoder auto correct func-
tion. To enable the function use a 1, to disable the function use a 0. When this function is
enabled, the relative register is used to calculate the encoder position, therefore before the
next move is made, the relative register needs to be set. This command is used in con-
junction with the encoder delay “ED”, encoder ratio “EM”, encoder retries “ER” and encoder
window “EW” commands.
July 2018