background image

SA-132  Instruction Manual – Guide d’utilisation 

 

Telephone Paging Input 

This special input (terminals 1 and 3) will allow you to page in your PA system using your own telephone set. Pin 
2 is Ground and Pin 4 is for manual priority switching. Any signal going through Pin 3 with automatically triggers 
the priority system without any manual intervention. At the end of the announcement, the system will return to 
its  normal  operation.  A  Gain  control  is  located  next  to  the  input  in  order  to  increase  incoming  volume  if 
necessary. Final adjustment will be made with the Tel Paging volume control located on front panel.  
 

Recommendations 

Keep your amplifier away from excessive humidity, dust or grease. This unit has sensitive components that can 
be  affected  in  a  difficult  environment.  If,  at  one  point  during  its  usage,  the  fuse  on  the  AC  line  needs  to  be 
changed make sure that the replacement is of the same value. It is important that you try to identify the reason 
for  this  failure.  This  will  most  likely  prevent  further  damage  to  your  amplifier.  Any  service  work  on  this  unit 
should be performed by a qualified technician. 
 

Power saving feature

 

Note that this unit will automatically shut-off after a one-minute audio signal interruption.  
 
 
 

SA-132  TECHNICAL SPECIFICATIONS  

 
Output in RMS 

130W 

AC 117v 60Hz 

4 Amp. Fuse 

THD at Rated Power 

2.5% 

Speaker Outputs 

4Ω, 8Ω, 16Ω, 70V, 100V 

Frequency Response 

100Hz – 20KHz 

Microphone Input 

1mV @ 600Ω 

AUX Input 

200mV @ 50KΩ 

CD Input 

500mV @ 50KΩ 

Telephone Paging Input 

100mV – 900mV (bal.) 

Music on Hold Output 

1W max @ 32Ω 

Sig/Noise Ratio, Mic 

>60dB 

Sig/Noise Ratio, AUX/CD 

>70dB 

Tone Controls 

±10dB 

Dimensions HxWxD mm 

90x430x270mm 

Weight 

10.5kg 

 

 
 

Содержание SA-132

Страница 1: ...A AMPLIFIER 1 AC Line socket 1 Prise AC 2 Fuse compartment 2 Support du fusible 3 Ground screw 3 Vis pour mise à la terre 4 Manual Priority terminals 4 Terminaux priorité manuelle 5 Speakers output terminals 5 Terminaux pour haut parleurs 6 AUX Input 6 Entrée AUX 7 CD Input 7 Entrée CD 8 AUX CD Selector Switch 8 Sélecteur AUX CD 9 Music on Hold Volume Control 9 Contrôle de musique en attente 10 Mi...

Страница 2: ...esigned for a multiple speaker distribution When using the 70V output speakers have to be equipped with 70V transformer The maximum amount of speakers to be placed on your distribution line is in relation to the power allocated to each speaker The total wattage set on the secondary side of the transformers on your speaker line must not exceed the maximum RMS output power 30W or 60W Failure to resp...

Страница 3: ...s that can be affected in a difficult environment If at one point during its usage the fuse on the AC line needs to be changed make sure that the replacement is of the same value It is important that you try to identify the reason for this failure This will most likely prevent further damage to your amplifier Any service work on this unit should be performed by a qualified technician Power saving ...

Страница 4: ...hée à une grande quantité de haut parleurs Lorsque la section 70V est utilisée les haut parleurs branchés doivent avoir des transformateurs 70V préinstallés Le nombre maximum de haut parleurs pouvant être branchés sur la ligne est en proportion à la puissance allouée à chacun des ces derniers La puissance totale allouée aux haut parleurs ne doit pas dépasser la puissance RMS de l amplificateur soi...

Страница 5: ...ent inapproprié Si par hasard vous deviez durant son utilisation changer son fusible assurez vous de le remplacer par un de même valeur Il est aussi important que vous puissiez trouver la raison de cette perturbation afin de prévenir des dommages subséquents plus sérieux à votre appareil Toutes réparations sur votre amplificateur devront être effectuées par un technicien compétent Caractéristique ...

Отзывы: