Wiring and Installation
8
IR Sensors and Receivers
!
To receive 455 kHz, position the jumper (both jumpers on the receivers) on the left two
pins, pins 1 and 2, away from the edge of the circuit boards, to receive 455 kHz. (This is
the default setting.)
!
To receive 38 kHz, position the jumper (both jumpers on the receivers) on the right two
pins, pins 2 and 3, near the edge of the circuit boards, to receive 38 kHz.
2.
Go on to the next procedure:
!
If you are installing a receiver, go on to Configuring the Receivers.
!
If you are installing an IR sensor, refer to Sensor IR validation level in Configuring the
Receivers before going on to Installation.
Configuring the Receivers
To configure the receivers, set the AXlink device number and the IR validation level.
Setting the AXlink Device Number
Perform the following steps to set the receiver's AXlink device number:
1.
Locate the eight-position Device DIP switch (FIG. 11).
2.
Set the DIP switch according to the DIP switch values shown in FIG. 12.
The device number is set by the total value of DIP switch positions that are ON (down). The
Axcess software program in your system typically uses device numbers 128 through 255 for
the panels.
FIG. 10
Receive frequency jumper settings
FIG. 11
IR receiver AXlink device DIP switches, IR validation jumper pins, AXlink connector, and receive
frequency jumper pin locations
Switch
1 2 3 4
5
6
7
8
Value
1 2 4 8 16 32 64 128
IR SNSR
38/455
kHz
Setting for 455 kHz
IR SNSR
38/455
kHz
Setting for 38 kHz (default)
IR validation jumper pins
AXlink Device DIP switch
AXlink connector