Signal Types & Specifications
40
Octaire Instruction Manual
Ultra-Wideband Video
Sync
* The input trigger voltage specification indicates the point which determines if the HV sync pulse is high or low.
An incoming sync signal below +1.75 V will be interpreted as low, and an incoming sync signal above +1.75 V will
be interpreted as high.
Ultra-Wideband (RGBHV) Signal Specifications
Frequency Response
Fully loaded
Fully loaded
Fully loaded
±3 dB, >600 MHz average
±3 dB, 500 MHz or better
±1.5 dB, 150 MHz or better
Crosstalk
f = 1 MHz
f = 5 MHz
f = 10 MHz
f = 30 MHz
f = 100 MHz
f = 150 MHz
<-80 dB
<-79 dB
<-74 dB
<-71 dB
<-60 dB
<-52 dB
Signal to Noise Ratio
Vin = 0.7 V, 100 IRE
>65 dB
Return Loss
f = 5 MHz
<-45 dB
Input Level (max.)
±1.0 V
Input Impedance
75 ohms
Output Level (max.)
±1.0 V
Output Impedance
75 ohms
Connectors
BNC
Sync Signal Specifications
Input Level Signal Range
0 to +5 Volts
Input Impedance
510 ohms
Input Trigger Voltage*
+1.75 V
Input Polarity
Output polarity follows input polarity Active high or low
Output Level Signal Range
0 to +5 Volts
Output Impedance
50 ohms
Output Polarity
Output polarity follows input polarity Active high or low
Connectors
BNC
Содержание Distribution Matrix Octaire
Страница 1: ...Instruction Manual Matrix Switchers Octaire Distribution Matrix Release 08 15 2008...
Страница 11: ...Notices 6 Octaire Instruction Manual...
Страница 43: ...Installation Setup 38 Octaire Instruction Manual...
Страница 47: ...Signal Types Specifications 42 Octaire Instruction Manual...
Страница 71: ...Octaire Control Panel Operation 66 Octaire Instruction Manual...
Страница 101: ...Appendix A Octaire AutoPatch Connector Guide 96 Octaire Instruction Manual Appendix A Octaire AutoPatch Connector Guide...
Страница 105: ...Appendix B Programmer s Interface for System Diagnostics 100 Octaire Instruction Manual...