Installation & Setup
24
Octaire Instruction Manual
Attaching External Control
Note: The Octaire
has a fixed configuration that was programmed at the factory.
The Octaire can be controlled externally by attaching a control device that uses one of the
communication protocols listed below:
BCS
(Basic Control Structure)
– ASCII sent over a null modem serial cable via RS-232
XNNet
– AMX AutoPatch protocol via RS-232
TCP/IP
– See “Connecting to the APWeb Server” on page 35
In a multi-enclosure Octaire system, only the primary enclosure (with control panel) is enabled for
external control via the serial port or TCP/IP port. Serial ports on secondary enclosures are primarily
intended for single enclosure diagnostic information and system firmware upgrades.
Control Options
The communication protocols listed above are used for these control options:
NetLinx
®
AMX AutoPatch distribution matrices are NetLinx
®
compatible and support Device Discovery.
For specific control programming information, contact your AMX representative.
Important: Device Discovery functionality (beacon response) will only function properly if the
NetLinx master is connected to the RS-232 control port on the primary enclosure (the one with
the control panel).
APControl 3.0
APControl 3.0 software (for control and scheduling) runs on a PC connected to an Octaire via the serial
port (DB-9) on the primary enclosure and is available on the
AMX AutoPatch CD
.
APWeb (TCP/IP)
The APWeb server (for control, diagnostics, and third-party access) is accessed through a TCP/IP
interface such as a web browser (e.g., Internet Explorer). The Octaire TCP/IP port is used to access
APWeb. For connecting to the APWeb server, see page 35. For APWeb Server setup and operation
information, see the “APWeb – Initial Setup by Network Admin” chapter on page 67 and the “APWeb –
Controlling the Octaire” chapter (page 87).
Important: Contact AMX regarding limitations and conditions for operating an Octaire on a company
LAN.
XNNet Protocol (Serial)
Advanced programmers who want to design their own control programs can use AMX AutoPatch
XNNet protocol. The
AMX AutoPatch CD
includes the XNNet Communication Library, an interface
library that supports C, Java, and Visual Basic with examples of the XNNet protocol in use.
BCS (Serial) Control
AMX AutoPatch has developed a command language, BCS (Basic Control Structure), for executing
control operations and for diagnostic purposes. BCS commands are issued via a terminal emulation
program, such as Windows
®
HyperTerminal. For information on BCS commands, see the
BCS Protocol
Instruction Manual
on the
AMX AutoPatch CD
and at
www.amx.com
.
Third-Party Controllers (Serial)
Third-party controllers connect to the serial port (DB-9) on the right rear of the primary enclosure.
If using a third-party controller, see the controller documentation for setup and operating instructions.
Содержание Distribution Matrix Octaire
Страница 1: ...Instruction Manual Matrix Switchers Octaire Distribution Matrix Release 08 15 2008...
Страница 11: ...Notices 6 Octaire Instruction Manual...
Страница 43: ...Installation Setup 38 Octaire Instruction Manual...
Страница 47: ...Signal Types Specifications 42 Octaire Instruction Manual...
Страница 71: ...Octaire Control Panel Operation 66 Octaire Instruction Manual...
Страница 101: ...Appendix A Octaire AutoPatch Connector Guide 96 Octaire Instruction Manual Appendix A Octaire AutoPatch Connector Guide...
Страница 105: ...Appendix B Programmer s Interface for System Diagnostics 100 Octaire Instruction Manual...