background image

Using NetLinx Studio

20

DXP-HT v1.3 - On-Site Installer’s Guide

6.

Click the 

Edit Settings

 button to open the Serial Settings dialog. 

7.

Make sure the correct serial port is selected and the baud rate is correct on the Master Comm 

Settings dialog (in the Tools menu). Set the COM port parameters for the selected COM port 

being used for communication to the NetLinx Master. Default parameters are: COM1, 38400, 

8 Data Bits, No Parity, 1 Stop Bit, and No Flow Control.

8.

Click 

OK

 three times to close the open dialogs and save your settings.

9.

Click on the OnLine Tree tab in the Workspace window to view the devices on the System. The 

default System value is one.

10.

Right-click on the 

Empty Device Tree

 entry and select 

Refresh System

 to establish a new 

connection to the System's Master and refresh the list with online system devices. The 

communication method is highlighted in green on the bottom of the NetLinx Studio window.

Obtaining the Master's IP Address:

1.

Once a connection is made, select 

Diagnostics > Network Addresses

 from the Main menu to 

access the Network Addresses dialog.

2.

Verify the System number corresponds to the value previously assigned in the Device 

Addressing tab and verify that zero (0) is entered into the Device field.

3.

Verify that NetLinx appears in the 

Host Name

 field.

4.

Click the 

Use DHCP

 radio button from the IP Address section.

5.

Click the 

Get IP Information

 button to read the IP Address obtained by the Master from the 

DHCP Server and configure the unit for DHCP usage.

6.

Note the obtained IP Address. This information is later entered into the Master 

Communication Settings dialog and used by NetLinx Studio 2.1 (or higher) to communicate to 

the Master via an IP. This address is reserved by the DHCP server and then given to the Master.

7.

Click the 

Set IP Information

 button to retain the IP Address on the Master. A popup window 

then appears to notify you that Setting the IP information was successful and it is 

recommended that the Master be rebooted.

8.

Click 

OK

 to accept the new changes.

9.

Click the 

Reboot Master

 button and select 

Yes

 to close the Network Address dialog. This 

process closes the Network Addresses dialog and directs you to the Reboot the Master 

Controller dialog.

10.

Click 

Continue

 (from the Reboot Controller dialog) and wait for the System Master to reboot 

and retain the newly obtained DHCP Address. The STATUS and OUTPUT LEDs should begin 

a alternately blink during the incorporation. Wait until only the STATUS LED is the only LED 

to blink.

11.

By default, the Master ships with the option set to wait for a server to assign it an IP Address 

via DHCP. If there is no DHCP server on the network it will greatly increase startup time while 

the Master waits for an address to be assigned. Therefore, it is recommended that the IP 

Address be set to a Static Address.

Содержание DESIGN XPRESS HOME THEATER V1.3 - ON SITE INSTALLER GUIDE

Страница 1: ...instruction manual Software Design XPress Home Theater version 1 3 On Site Installer s Guide...

Страница 2: ...be repair or replacement of the AMX Software that does not meet AMX s Limited Warranty and which is returned to AMX This Limited Warranty is void if failure of the AMX Software has resulted from acci...

Страница 3: ...for Radia Lighting Systems 4 Supported Subsystems and Equipment 5 Modero G4 touch panels 5 G3 touch panels 6 G3 panels do not support the following 6 AMX NetLinx Integrated Controllers 6 CD Players 6...

Страница 4: ...s AMX Recommended Equipment List 17 Using NetLinx Studio 19 Setting Up the Master 19 Obtaining the Master s IP Address 20 Addressing the System 21 Addressing the Devices 22 Downloading Software and Tr...

Страница 5: ...gram files touch panel files and a comprehensive report file for the system While these auto generated program files can be used as is they can also be modified using NetLinx Studio allowing the deale...

Страница 6: ...be avoided and the steps required for installing the system Related Documents The following related documents are available for download at www amx com One Step at a Time DXP HT is easiest to install...

Страница 7: ...r the AMX Radia the address is the AXlink address of the Radia MC The only valid keypad address characters are 0 9 A F and colon For reference here are the formats for the various supported lighting s...

Страница 8: ...rs Tech Center Tech Notes Note for Radia Lighting Systems On Radia lighting systems channels 1 128 represent Radia lighting presets 1 128 If a channel is on then the corresponding preset is on However...

Страница 9: ...tion Devices Receivers Serial Interface Devices Modero G4 touch panels For a more up to date list of supported devices refer to the DXP HT Supported Devices document available online at www amx com Mo...

Страница 10: ...0 AXT D CA10 10 4 touch panel CV10 AXT D CV10 10 4 touch panel with video The nomenclature AXT indicates the table top tilt model and AXD represents the wall mount version NI 700 NI 2000 NI 3000 NI 40...

Страница 11: ...MS and MAX IMS Installation Guides available online at www amx com for details Lighting MP3 Players Philips Pro DVD 175 Sony DVP CX777ES Yamaha DVD C940 Yamaha DVD S2300MK2 AMX MAX IMS MAX BSM AMX MAX...

Страница 12: ...43HDX Runco PL50HDX Runco PL61GX Samsung SyncMaster 403T Sharp LCM3700 Denon AVR2803 Denon AVR3803 Denon AVR4802 Denon AVR 5800 Denon AVR5803 Integra DTR 9 1 Integra Research RDC 7 Kenwood VR5700 Kenw...

Страница 13: ...n PowerLite811p Epson PowerLite8150i Epson PowerLite8300i Hewlett Packard XP8010 InFocus SP7200 Marantz VP12S1 Marantz VP12S2 NEC Any GT Series NEC Any LT Series NEC Any MT Series NEC Any SX Series Op...

Страница 14: ...could use the DXP HT application as a starting point The resulting files could get most of the job complete Not a bad start The installer could then go in and modify the software to be job specific a...

Страница 15: ...DXP HT is not a simple NetLinx program Because of the scope and number of features designed into the system the code can be quite daunting to someone looking at it even an experienced NetLinx programm...

Страница 16: ...On Site Installer s Guide Overview 12 DXP HT v1 3 On Site Installer s Guide...

Страница 17: ...te via Ethernet 6 Compile the project 7 Go to the download screen Make sure communications settings are correct 8 Select all files in the project and download 9 Using an FTP program FTP all TXT files...

Страница 18: ...rt 10 IR Pulse Time 5 10 seconds Time Gap Between IR Pulses 5 10 seconds IR Pulse Time for Power 5 seconds Time Gap Between IR Power Pulses 5 seconds Uses Carrier Signal XCHMode 0 Serial Devices Switc...

Страница 19: ...les AMX Control Disc Design XPress Home Theater Projects QRA Test Rack build 5 Rev 3 cd_cd txt DVD C Program Files AMX Control Disc Design XPress Home Theater Projects QRA Test Rack build 5 Rev 3 dvd_...

Страница 20: ...Yes Childrens MTV 331 Yes VH1 335 Yes ESPNEWS 207 Yes News VH1 Classic 337 Yes Headline News 204 Yes NetLinx include files copied to C PROGRAM FILES AMX CONTROL DISC DESIGN XPRESS Home Theater Project...

Страница 21: ...ach Macro has been added Example Macro MAX 1_1 Navigation and Routing Send Plasma command Power On Execute delay of 1 second Send Plasma command BNC of type Video Inputs Execute delay of 1 second MAX...

Страница 22: ...Understanding the Report File 18 DXP HT v1 3 On Site Installer s Guide...

Страница 23: ...controlling lights via the touch panels All of the touch panel files are located under the User Interface branch The text files and report file are located under the Other branch To compile your proje...

Страница 24: ...DHCP radio button from the IP Address section 5 Click the Get IP Information button to read the IP Address obtained by the Master from the DHCP Server and configure the unit for DHCP usage 6 Note the...

Страница 25: ...There is no need to modify the device ID of the Master unless the system is being installed in a multi Master system However the device ID of the NXI may need to be changed DXP HT expects this device...

Страница 26: ...ther things to get done Once the new device shows up in the online tree its device ID and device type is displayed Use this device ID to change to the new value specified in the report file To change...

Страница 27: ...o load the new configuration Running the First Time The master ships with a default message buffer threshold which may be too small for the Design XPress system Fortunately there is a solution to this...