Appendix B – Error Code Reporting
42
Instruction Manual – BCS Basic Control Structure Protocol
Enabling Error Code Reporting
Error code reporting can be enabled or turned off with BCS commands entered into a terminal emulation
program.
To enable error code reporting:
1.
Enter
$ERR=1!
The system responds with
V
.
Note:
If the power is cycled, you will need to enable error code reporting again.
To turn off error code reporting:
1.
Enter
$ERR=0!
Common System Error Codes
The table below lists the error code, the name of the code, the meaning of the code, and some basic
troubleshooting strategies. This list is not intended to be comprehensive, nor does it apply to all
products. If an error code appears that is not listed, note the specific number and contact technical
support
(see page 43).
Most Common System Error Codes
Error Code
Meaning
Troubleshooting Strategies
E01000A
Enclosure
timeout error
One or more of the enclosures in a
multi-enclosure system did not
acknowledge a control operation
command.
• Resend the command.
• Check the Status LED on the rear of each enclosure.
If any of the LEDs are red, contact technical support.
• Check the power indicators.
• Check the link connectors between enclosures.
EFF8002
Transaction
timeout error
The operation was not completed
before the timer expired.
• Resend the command.
• Check the power indicators.
• Check the link connections in multi-enclosure systems.
• Check that the level used in the command was valid.
E01DFFF
Audio
request
error
Missing hardware support error, e.g.,
a volume or gain request was made
on a level that does not switch audio.
• Resend the command on a level that includes audio.
W010005
Sync timeout
error
The system did not receive the vertical
interval sync signal. Note that the
switch occurred, but not at the sync
interval.
• Resend the command.
• Check the sync cable connections.
• Check the HyperTerminal splash screen to verify that sync is
enabled (see the vertical interval sync board / connector
documentation).
• Check that the sync signal from the generator is being
received by the system.
• Power the system down and check sync board alignment.
Содержание BCS
Страница 22: ...Adjusting and Verifying Audio 19 Instruction Manual BCS Basic Control Structure Protocol ...
Страница 27: ...Adjusting and Verifying Audio with DSP 24 Instruction Manual BCS Basic Control Structure Protocol ...
Страница 43: ...Appendix A Product Specific BCS Commands 40 Instruction Manual BCS Basic Control Structure Protocol ...
Страница 47: ...Appendix B Error Code Reporting 44 Instruction Manual BCS Basic Control Structure Protocol ...