16
Installation
AXP-CCV/AXM-CCV Color Video Camera Centers
PWR +
Control system
1
2
3
4
GND -
12 VDC power supply
GND -
2
1
PWR +
AXM
AXP
3
4
1 - GND -
3 - AXP
2 - AXM
4 - PWR +
4-pin mini-XLR connector
(external view)
Using AXM-CCV AXlink connector for data and power
Connect the control system’s AXlink connector to the AXlink connector (male) on
the rear panel of the AXM-CCV, for data and 12 VDC power as shown in Figure 18.
PWR+
AXM
AXP
GND -
AXlink connector
Control system
PWR
AXM
AXP
GND
Figure 17
Mini-XLR connector to external
12 VDC power supply, and
control system wiring diagram
Caution
If you are using power from
AXlink, disconnect the wiring
from the control system before
wiring the AXM-CCV.
Figure 18
AXlink wiring diagram