Product Information
4
AXB-PCCOM Communications Port Interface
AMX standard device numbers are assigned as follows:
Cards are 1 through 25.
Boxes are 96 through 127.
Panels are 128 through 255.
The AXB-PCCOM emulates as a touch panel. Set the device number to one in the panel range.
Connectors
Preparing/connecting captive wires
You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
1.
Strip 0.25 inch of wire insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector according to the wiring
diagrams and connector types described in this section.
3.
Do not tighten the screws excessively; doing so may strip the threads and damage the
connector
Using the AXlink connector for data and power
To use the AXlink 4-pin connector for data communication and for power supply, the incoming
PWR and GND cable from the control system must be connected to the AXlink cable connector
going to the control system. The AXlink connector is located on the side of the PCCOM (FIG. 4) is
a four-wire, captive compression connector.
Install the AXlink data/power as sown in the AXlink wiring diagram (FIG. 5).
Never pre-tin wires for compression-type connections.
FIG. 4
AXlink connector location on AXB-PCCOM
FIG. 5
AXlink connector wiring diagram
Four-pin AXlink connector
PWR +
AXP/TX
AXM/RX
GND -
PWR +
AXP/TX
AXM/RX
GND -
To the AXB-PCCOM
To the Control system