Installing a CP-10 Remote Control Panel
14
CP-10 Instruction Manual
Applying Power
Power Requirements
AMX
AutoPatch wall transformer
Or
+7 VDC to +12 VDC @
500
mA
Important: Always use a UL approved power source. Be sure to check the power source
documentation for information specific to that power source.
The instructions below are for using the (optional) AMX AutoPatch wall transformer. If you use the
AMX AutoPatch transformer, the side of the wire with the white stripe is positive and the other side is
ground.
To apply power to the CP-10 Remote using the wall transformer:
1.
Unplug the CP-10 Remote’s power connector.
2.
Loosen the ground and positive screws.
3.
Insert the power cable ground and positive wires into the slots (FIG. 7) and tighten the screws.
4.
Plug the power connector back into the CP-10 Remote.
5.
Install the CP-10 Remote in a rack (see page 15) or other permanent location before plugging the
transformer into the power source.
FIG. 7
Remove power connector, wire it, and replace
Positive
Ground