Note

: If you will be fixing personnel photos to the ANT-BDG, use a Badge/Slot Punch 

capable of a throat reach of 1/4” (FIG. 2). 

Connecting the ANT-RDR To a NetLinx Master

The ANT-RDR uses a single 4-pin captive-wire AxLink port to connect the ANT-RDR to a 
NetLinx Master, and (optionally) to other ANT-RDRs. To connect the ANT-RDR to the 
NetLinx Master via AxLink, install the AXlink data/power bus wiring as shown in FIG. 3.

Connecting Additional ANT-RDRs

To connect additional ANT-RDRs to create a RFID Reader Network Group, follow the 
standard AxLink bus wiring (FIG. 4). 

Preparing And Connecting Captive Wires

1.

Strip 0.25 inch of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector according to the 
wiring diagrams and connector types described in this section.

3.

Tighten the screws to secure the wires. Do not tighten the screws excessively; doing 
so may strip the threads and damage the connector.

Assigning the ANT-RDR Device Address

The ANT-RDR sets its unique AXLink address via the 8-position DIP switch located on the 
rear panel (see FIG. 1). AXLink addresses must be in the range of 1 to 255 (address 0 
belongs to the Master). 

Note

: The device number takes effect only upon power-up. If you later change the device 

number, remove and reconnect the AXlink connector to cycle power to the unit and enter 
the new device number into memory.

Anterus Configuration Manager

The Anterus Duet Module interfaces ANT-RDR Readers with NetLinx controllers, and adds 
the Anterus Configuration Manager to the NetLinx Master’s built-in web console. 
The Anterus Configuration Manager allows you to configure the Reader and all Tags in the 
Anterus solution via a web browser on any PC that has access to the NetLinx Master to 
which the ANT-RDR is connected. 
A sample UI module is provided in the module package. It is not intended to cover every 
possible application, but can be expanded as needed to meet the requirements of a 
particular installation. Refer to the documentation supplied with the Anterus Duet Module 
for more details.

Note

: The Anterus solution will also work without the Duet module, and all web 

configuration may be done with Send Commands, Channels and Levels. Refer to the 
Anterus RFID Solution Operation/Reference Guide for detailed programming information. 

Accessing the RFID Configuration Manager

From any PC that has access to the LAN that the NetLinx Master to which the ANT-RDR is 
connected:
1.

Open a web browser and type the 

IP Address

 of the target NetLinx Master in the 

browser’s Address Bar. 

2.

Press 

Enter

 to access the Configuration Manager for the specified NetLinx Master.

Note

: If the specified NetLinx Master requires authentication, you will have to provide a 

valid Username and Password to proceed.

3.

The initial view is the Master’s 

Master Configuration Manager

 page - 

Web Control

 

tab.

4.

Click the 

System

 button to access the 

Manage System

 page. The initial view is of the 

Manage System

 tab. 

5.

Open the 

Manage Devices

 tab.

6.

Under 

Device Configuration Pages

, click on 

RFID

, then select 

AMX Anterus

 

(FIG. 5). 

This opens the RFID Configuration Manager (Main page).

RFID Configuration Manager (Main page)

The first web configuration page to be displayed when the ANT-RDR Web Console is 
accessed is the 

RFID Configuration Manager 

page (FIG. 6). 

The options in this page allow you to view and configure the Anterus system (Readers and 
tags) as a whole (Global Settings), as well as view and configure each ANT-RDR Reader in 
the system individually. Configuration options include naming each ANT-RDR, and 
managing each of the RFID Tags in the system.

Adding a Tag to the System

1.

Click the 

Add Tag

 button in the bottom-left corner of the 

Global Register 

page to add 

a new RFID Tag to the system. This invokes a set of fields for the new Tag (FIG. 7): 

2.

Enter a Tag 

Name

.

3.

Enter Tag 

Info

.

4.

Enter the desired 

Acquired Threshold

 value for the new tag.

5.

Click on the 

Accept

 button to enter the newly defined tag into the system.

Reader Configuration Page

Click the Configure icon for any Reader (in

 

the 

RFID Configuration Manager

 page) to 

access the 

Reader Configuration 

page. The top section of this page provides configuration 

options for the selected ANT-RDR. 

Note

: The Reader configuration options on this page are identical to those presented on the 

Global Register page. The difference between the two is that the options on the Reader 
Configuration page are specific to the ANT-RDR selected on the RFID Configuration 
Manager (Main page).

The lower section of this page provides configuration options for each Tag assigned to this 
Reader.

Additional Documentation

Refer to the Anterus™ RFID Solution Operation/Reference Guide for additional 
programming information and a full description of the Configuration Manager.

FIG. 2  

ANT-BDG - Slot Punch dimensions

FIG. 3  

AXlink data/power connections

FIG. 4  

Connecting Additional ANT-RDRs

Device DIP Switch Settings

Position

1

2

3

4

5

6

7

8

Value

1

2

4

8

16

32

64

128

Depth = .25” (6.35mm)

Punch-out width = 1.625” (41.27mm)

Punch-out height = 
.25” (6.35mm)

PWR

AX

P

AX

M

GND

ANT-RDR

NetLinx Master

PWR

AX

P

AX

M

GND

PW

R

AX

P

AX

M

GND

ANT-RDR

NetLinx Master

PW

R

AX

P

AX

M

GND

PW

R

AX

P

AX

M

GND

PW

R

AX

P

AX

M

GND

PW

R

AX

P

AXM

GND

ANT-RDR

ANT-RDR

ANT-RDR

1 2 3 4

 

5

 

6 7

8

ON

 

Example: Device #128

FIG. 5  

Manage Devices tab - Device Configuration Pages options

FIG. 6  

RFID Configuration Manager - Main Page (initial view)

FIG. 7  

New tag fields

"Global Settings" indicates the entire Anterus System (ANT-RDRs and Tags)

Click to access the 

Global Register

 page

Click to access the 

Reader Configuration

 page for each ANT-RDR.

Settings made to individual Readers will override Global settings.

Listing of all ANT-RDRs currently connected to this NetLinx Master.

Click to re-initialize the RFID System

Click to refresh the web console

Click to add a Tag

Click to delete a Tag