3-5. Making DC Wiring Connections
:
Follow this procedure to connect the battery cables to the DC input terminals
of the Inverter. Your cables should be as short as possible (Ideally,
less than 6 feet / 1.8 meters ) enough to handle the required current in
accordance with the electrical codes or regulations application. Cables are
not an adequate gauge (too narrow) or too long will decrease the inverter
performances such as poor surge capability and low input voltage warnings
frequently and shutdowns. UVP warning presents due to DC voltage drop
across the cables from the inverter to the batteries.
The longer or narrower the cables, the greater the voltage drop.
Increasing your DC cable size will help improve the situation.
Following cable recommendations for the best performance of inverter.
(Apply both 120V and 230V versions )
Model No
Wire AWG
Inline Fuse
SK3000-112 #
4/0
400A
SK3000-212 #
4/0
400A
SK3000-124 #
2/0
200A
SK3000-224 #
2/0
200A
SK3000-148 #
1/0
100A
SK3000-248 #
1/0
100A
WARNING!
Make sure all the DC connections are tight (torque
to 9 – 10 ft-lbs, 11.7 – 13 Nm). Loose connections
could result overheat in a potential hazard.