![Amtrol WELL-X-TROL WX-101 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/amtrol/well-x-trol-wx-101/well-x-trol-wx-101_installation-and-operation-instructions_2937126006.webp)
Start Up
Fine Tuning Procedures
1.
Restore power and pressurize system until pump cuts off.
2.
Open one or more fixtures to reduce pressure and initiate a
pump cycle.
3.
Check operation. Make adjustments only when the tank is
empty of water and the system is off.
Adjusting Precharge After Installation
Step 1.
Drain tank of all water. Check precharge pressure in the
Well-X-Trol Tank.
Step 2.
Release or add air as necessary to set the precharge
pressure 2 psig below the pressure switch pump cut-in setting.
Maintenance
A licensed professional should check the complete system,
including the Well-X-Trol, yearly and more frequently as the
system ages.
Warranty
WX Models: Seven (7) Year Limited Warranty
Visit www.amtrol.com for complete warranty details and to
register the serial number of your well tank.
Pressure Adjustment:
• Clockwise to increase
cut-out pressure.
• Counter-clockise to decrease
cut-out pressure.
Figure 2
© 2019 Worthington Industries, Inc. Part #: 9015-868 MC10185 (09/19)
1400 Division Road, West Warwick, RI USA 02893
T: 800.426.8765
www.amtrol.com