Amtrol WELL-X-TROL WX-101 Скачать руководство пользователя страница 4

Suggested Piping Diagrams

In-line Models:

 

Horizontal Models:

Underground Models:

All Well-X-Trol Underground Tanks

 are designed for direct 

burial and must be installed 

in the vertical position only

. To 

eliminate danger of freezing, tank should be buried below the 

frost line.
The following steps should be taken when installing a Well-X-Trol 

Underground Tank:

1.

  Make sure that the tank will be buried below the frost line and 

above the water table.

2.

 Remove plastic bag and check tank precharge. Factory 

precharge is 38 psig. Replace air stem cap securely. Follow 

adjusting precharge procedure.

3.

  Important: Install tank vertically connector end down as shown 

on firm 

rock-free earth

. Do not bury in plastic bag.

4.

  The water lines from the pump to the tank and switch location 

should be the same size to prevent switch cycling.

5.

  Check the system for performance and inspect for leaks.

6.

 Important: Backfill hole with sand. Firmly tamp fill to prevent 

settling. Failure to do so will shorten tank life.

7.

  Fill out pressure tank location sticker and affix to power panel 

or other visible surface so tank can be easily located at a  

later time.

WELL-X-TROL

JET

PUMP

RELIEF VALVE

WELL-X-TROL

POSSIBLE PRESSURE

SWITCH LOCATION

RELIEF VALVE

BUILDING FOUNDATION

TO HOUSE

WELL-X-TROL 

"UG"

ROCK FREE

COARSE SAND

PUMP

PRESSURE TANK LOCATION

STICKER SUPPLIED WITH

EACH UNIT

PRESSURE TANK LOCATION,

FOR EXAMPLE

WELL

110

N

E

S

W

FROST LINE

(O)