STARTUP

1. 

After plumbing and wiring are complete, close the service 

valve to allow startup without pressurizing the entire 

plumbing system. If a service valve was not installed, 

close all fixtures in the home. Ensure the bottom drain  

is closed.

2.

  Restore power to the Well-X1

®

 by turning on the breaker 

and electrical service switch (if installed). The display  

will illuminate.

3.

  The display will read "

88

" to test the display illumination, 

then a number identifying the control type (i.e. 

15

). This 

number is for factory use and may vary by model and 

manufacture date.

4.

  After a slight pause, the pump will start and the system 

pressure will be displayed. This number will increase as 

the pump runs and the tank fills.

 Note:

 Some jet pumps may be difficult to prime, resulting 

in the low water cut-off activating if pressure will not build 

above 10 psig. Depressing the 

s

 

arrow will temporarily 

override the low water cut-off to allow proper priming.

The factory cut-out (pump off) setting is 60 psig. 

When the pump reaches 60 psig, the Well-X1 will 

shut the pump off. Check the plumbing for leaks and 

repair before continuing. If during startup the cut-

out setting of 60 psig cannot be reached, read the 

adjustment instructions to lower the cut-out within the  

pump’s capability.

6.

  Slowly open the service valve to allow the system to 

pressurize. The pressure may drop slightly during this 

process. After the valve is fully open, open the fixture 

closest to the Well-X1 to begin drawing water from  

the tank.

7.

  When the system reaches the factory cut-in (pump on) 

setting of 40 psig, the pump will start. Like a traditional 

mechanical switch, the pressure will begin to rise, 

repeating the cycle. If desired, the Well-X1 settings can 

now be adjusted as shown.

DISPLAY

TO
SYSTEM

FROM
WELL

CLOSE
SERVICE
VALVE

OPEN CLOSEST
FIXTURE TO 
DRAW WATER

OPEN SERVICE VALVE
TO PRESSURIZE SYSTEM

Содержание WELL-X-TROL WELL-X1

Страница 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Страница 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Страница 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Страница 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Страница 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Страница 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Страница 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Страница 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...

Отзывы: