background image

MARK OF THE 

ORIGINATOR

CODE

REASON

ACTION

CAUSE & REMEDY

E1

Rapid cycle

Excessive amp draw

Switch continues to operate.

See “Pump Starts Too Often” above.

Have pump checked for proper operation.

E2

Low-suction 

(running pressure)

below 10 PSI 

Shuts off pump. Auto restart 

after 60 min.

1. Determine cause of low-suction.

2. Check Wiring.

3. Inspect pump.

E3

Improper voltage

Shuts off pump.

Restore voltage to proper range. Pump automatically 

restarts with proper voltage.

To reset control at any time, press  

 

 

 buttons simultaneously for 5 seconds.  

To "invert" the display for easier viewing, press  

  

  together for 3 seconds.

The Guardian CP

 incorporates built-in diagnostics. If the AMTROL Pressuriser

®

 is not functioning properly or is inoperable, look for 

a error code (example E1) on the digital readout before proceeding. Error codes are listed in the table at the bottom of this page.

PROBLEM

CAUSE

SOLUTION

Pump will not start.

1. No Power.
2. Faulty wiring.

3. Damaged motor.

4. Damaged control.

1. Check circuit breaker and fuses, tighten connections.
2. Check wiring per installation diagram in this booklet. If pump hums, 

but will not start, check pump motor wiring (115/230V).

3. If display illuminates with no error code, but pump will not start, 

replace pump.

4. If power is present at L1/L2 but display is blank, replace control.

Pump runs but will 

not build pressure.

1. Supply closed/blocked.

2. Bypass loop open.
3. Pump plumbed backwards.
4. Bad internal parts.

1. Open all supply valves, ensure check valve is not sticking, clean 

any filters.

2. Close bypass valve.
3. Reverse inlet/outlet.
4. Check for bad seals or broken impeller. Repair or replace as 

necessary.

Pump builds 

pressure but will not 

shut off.

1. Operating pressure set too high.
2. Bad internal parts.

3. Control line blocked.

1. Reduce control setting as necessary.
2. Check for bad seals or broken impeller. Repair or replace as 

necessary.

3. Remove control line and blow compressed air to clear.

Pump starts too often 

(cycles under 30 

sec.).

1. Control differential too narrow.
2. Tank precharge incorrect.

3. Waterlogged pressure tank.

1. Set cut-in and cut-out 20 psi apart.
2. Set air pressure 2 psi below cut-in while pump is off and gauge 

pressure is zero.

3. If water emerges from tank air stem when depressed, replace tank.

THE GUARDIAN CP CONTROL CONTAINS NO SERVICEABLE PARTS. REMOVAL OF MAIN CIRCUIT BOARD COVER WILL 

VOID WARRANTY.