AMTAST AMT-316 Скачать руководство пользователя страница 4

4

Press E3 key again to display the stun on the lower portion of the screen;

• Repeat the steps above can continue accumulation.

Addition (using M memory)

Press the M key to save the fust: measured result, and the "M+" will appear on the display,

Press the READ key for new measurement;

Press the key to enter the addition mode, and the "+" will appear on the display.

Press the RM key to recall previous measurement for the addition (displayed on the bottom of the

display).  and  at  the  same  time,  the  "M+"  icon disappears  and  the  stored  memories  will  be
automatically eliminated;

Press +/= key, the sum is shown on the lower portion of the screen.

Area

Press SET key to enter area mode, and the will appear on the display for calculation of a room

area;

The length character "L" on the display will blink showing the length measurement you will be

firstly taking. Press READ key to take length measurement that is displayed on upper portion of
the screen. (Step 1);

The  width  character  "W"  on  the  display  will  blink  showing  the  next  measurement  to  take.

Press  READ  key  to  take  width  measurement  that  is  displayed  on  upper  portion  of  the  screen
(Step 2);

Then the area is automatically displayed on the lower portion of the screen;

Press  the READ  key  again  will  toggle  back  and  forth  between  the  length  and  width

measurement on the upper portion of the screen;

Содержание AMT-316

Страница 1: ...t more accurately and at the same time show the current enviIomnent temperatme precisely AMT 316 distance meer is the Class II laser tool confonning to IEC285 international safety rule SAFETY INSTRUCTIONS Failure to follow the inst ructions listed below may cause personal injiury Read and understand all instructions prior to any operation Do not remove any labels from the tool Do not operate the t...

Страница 2: ...this key to start the tool and read the measured distance keep pressing this key and move the tool to read values dynamically F SET Clear Menu press this key to clear or return back to the menu to select length area or vohune mode G Memory read key Read out and display the value of length area or volume that are stored in the last time H Addition key Add the measured length area or volume I level ...

Страница 3: ...ent or metric system original measuring unit Metric measurement Tips A The measured object must be nonnatively hard swface and not be blocked by any baniers B Select a smooth hard surface with big area to measure for precise result C If the measured surface is too small and iITegular or with soft mrface chipboard can be UBed on the surface of the measured object D The tool cannot measure through g...

Страница 4: ...Press key the sum is shown on the lower portion of the screen Area Press SET key to enter area mode and the will appear on the display for calculation of a room area The length character L on the display will blink showing the length measurement you will be firstly taking Press READ key to take length measurement that is displayed on upper portion of the screen Step 1 The width character W on the ...

Страница 5: ...section After getting the desired area of the second time computation press to enter the addition mode A icon would appear on LCD Press RM key to recall the first calctllated area for the addition The M icon will disappear and the stored memory will be automatically cleared Press 3 key the S1UJl of both areas is shown on the lower portion of the screen Repeal the slape above to keep adding the mea...

Страница 6: ...able Addition of volumes under volume mode Press M key to save the calculated volume of first time measurement and the M icon will appear on LCD Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section After getting the calculated volwne of second time press key to enter the addition mode A icon would a...

Страница 7: ...d be smooth hard and of homogeneity When the measuring enviromnent is not good the temperature and humidity will affect the accuracy of measurement and take measurement Wl der enviromnent of no wind and temperature of the unit should be same With temperature of the circlDllStance especially for long distance measuring between 40 to 53 12m to 16m the relative humidity should be above 480 0 and the ...

Страница 8: ...e The warranty does not apply to the following conditions Disassembling the laser tool will void the warnmty Any damage resulting from but not limited to wear water being dropped or repairs attempted by others ...

Отзывы: