AMT 569 Series Скачать руководство пользователя страница 1

Specifications Information and Repair Parts Manual  

     

569, 570, 571, 572 Series

                                                           

5690-250-00

1

11/2012

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

for future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2012 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to insure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

Patterson/AMT Inline Circulator Pump

Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.

 

All units are for use with non-flammable, non-abrasive liquids compatible 
with pump component materials.

IMPORTANT: Not for use with petroleum based liquids.

 

CAST IRON UNITS (-95)

Pump construction is cast iron casing and adapter. Cast stainless steel 
impeller; 5720 with cast bronze impeller. EPDM mechanical shaft seal with 
carbon and ceramic wear faces. EPDM O-ring casing seal.

BRONZE UNITS (-97)

Pump construction is cast bronze casing and adapter. Cast stainless steel 
impeller; 5720 with cast bronze impeller. EPDM mechanical shaft seal with 
carbon and ceramic wear faces. EPDM O-ring casing seal.

UNPACKING

Refer to Repair Parts Illustration and Repair Parts List to aid in identifying 
parts. Unpack and separate all pump components from shipping/packaging 
materials, making sure all parts are accounted for. Retain all manuals for 

reference.  Package  should  contain:  pump,  flanges,  circulator  pump  specific 

manual, and general pump manual. 

INSTALLATION

1. 

Pump is designed for circulating liquid in a closed system for a flooded 

suction application. Pump will not Self-prime.

2.  Piping system must be designed for adequate thermal expansion.
3.  A pressure relief valve should be considered to protect pump casing from 

over pressurization and pressure spikes especially if a check value is 
installed near pump. 

4. 

Locate  the  pump  so  that  there  is  sufficient  room  for  maintenance  and 

servicing.

5. 

There must be a sufficient supply of cooling air and ventilation around the 

pump and motor to avoid excessive component temperatures.

6.  Installing a shutoff valve in both the suction and discharge piping will 

make removal and servicing of the pump possible without draining the 
entire system.

7. 

Support the piping near the pump’s suction and discharge with sufficient 

piping hangers. This will minimize pipe strain.

NOTE: Proper motor support is required to avoid damage to pump or 
motor. Use correct size motor hanger similar to the one pictured based on 
model being installed. Hangers vary depending on horizontal or vertical 

installation (see figure 1). 

DESCRIPTION

Patterson/AMT inline circulator pumps are designed for continuous duty industrial/commercial applications. Pumps are designed for liquid circulation in HVAC 

and industrial/commercial systems. Pumps are available in cast iron or bronze configurations to meet your specification. Pumps are powered by a single phase 

115V 56J NEMA frame electric motor with ½-14 NPSM conduit connection. Pump is equipped with precision lapped mechanical shaft seal to reduce the likelihood 

of leakage, O-ring sealed casing, and a stainless steel closed impeller. Liquid temperature range is 40° to 200° F (4° to 93° C). Liquid viscosity and specific gravity 
must be close to water; 31 SSU and 1.00. Maximum casing pressure is 150 psi. Pump shipped without NPT connection flanges or flange gaskets. Connection 
flange kits must be ordered separately.

All 115V motors are equipped with automatic thermal protection. Check motor wiring before putting unit into service (see motor nameplate for specific wiring 
diagram). These are manual units, no controls are supplied. All units are for use with nonflammable, non-abrasive liquids, compatible with pump component 

materials.

8. 

Make sure bolt holes in pipe flange line up with bolt holes in pump flange.

 

Do  not  spring  the  suction  or  discharge  piping  into  position.  This  will 
result in excessive stain in the piping, flanges and pump casing. 

ORIENTING PUMP

1.  The pump can be oriented in any desired position: discharge up or down, 

left or right.

2.  If motor is oriented vertically up, a means of venting air from the seal 

chamber must be installed in the seal plate (Ref. No. 8) 1/8” NPT port. 
Remove 1/8” NPT plug (Ref. No. 6) and install air venting device or liquid 
injection line.

3.  DO NOT INSTALL UNIT

 with motor vertically down, any liquid breaching 

the mechanical shaft seal will run directly down shaft into motor. 

NOTE: Proper motor support is required to avoid damage to pump or 
motor. Use correct size motor hanger similar to the one pictured based on 
model being installed. Hangers vary depending on horizontal or vertical 

installation (see figure 1). 

Figure 1 - Piping Hanger & Support

Содержание 569 Series

Страница 1: ...e a sufficient supply of cooling air and ventilation around the pump and motor to avoid excessive component temperatures 6 Installing a shutoff valve in both the suction and discharge piping will make removal and servicing of the pump possible without draining the entire system 7 Support the piping near the pump s suction and discharge with sufficient piping hangers This will minimize pipe strain ...

Страница 2: ...cting casing Ref No 9 to adapter Ref No 2 2 Remove casing If casing is hard to slide off use a large flat screwdriver to pry between cast boss next to casing bolt boss and adapter flange Take care not to mar adapter flange machined surface Care should be taken not to pinch or shave casing seal Ref No 3 between adapter and casing 3 Use a box and or socket wrench to remove impeller fastener Remove i...

Страница 3: ...re starting this becomes essential with long suction line or static lift 9 Install valves in both suction and discharge lines to assist with pump inspection or repair Suction line valve may be opened completely during operation 10 Install a non slam non return check valve in discharge line between pump and isolation valve to protect pump from excessive back pressure and to prevent water running ba...

Страница 4: ... 5690 250 00 4 11 2012 For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 1 Repair Parts Illustrations Patterson AMT Inline Circulator Pump ...

Страница 5: ...PDM See Ref 13 See Ref 13 See Ref 13 See Ref 13 See Ref 13 See Ref 13 See Ref 13 See Ref 13 1 8 7 16 20 Acorn Nut 1784 001 00 1784 001 00 1784 001 00 1784 001 00 1784 001 00 1784 001 00 1784 001 00 1784 001 00 1 9 Casing 5690 001 01 5690 002 01 5700 001 01 5700 002 01 5710 001 01 5710 002 01 5700 001 01 5700 002 01 1 10 3 8 16 x 1 Hex Flange Bolt 4 11 5 16 18 x 3 4 Hex Fl Bolt 4 12 1 8 Pipe Plug 1...

Страница 6: ...Specifications Information and Repair Parts Manual NOTES ...

Страница 7: ......

Страница 8: ...www amtpump com ...

Отзывы: