AMT 4820-95 Скачать руководство пользователя страница 2

 

5540-251-00 

02/2012 

 

Specifications Information and Repair Parts Manual

 

 

 

                                                                   

4820-95 & 5540-95

 

 

 

x

 

Cast Iron Rotary Drum Pump 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GENERAL SAFETY INFORMATION (Continued) 

proper  use.  Consult  local  fire  department  for  the  correct 
type  of  extinguisher  for  your  application.  Extinguishers 
rated  ABC  by  the  National  Fire  Protection  Association  are 
appropriate for most applications. 

e. 

Provide  positive  shut-off  valves  on  all  permanent  fuel 

supplies.  Fuel  lines  must  be  of  steel  piping,  adequately 
secured, and free from leaks.

 

f. 

Provide  adequate  ventilation,  and  clean  up  any  spills  when 

handling or pumping flammable liquids. 

g. 

POSITIVELY NO SMOKING!

 

5. 

Do not use torches or apply fire to this pump for any reason. 

6. 

Secure  the  discharge  line  before  starting  the  pump.  An 
unsecured  discharge  line  will  slip,  possibly  causing  personal 
injury and/or property damage. 

7. 

Do  not  over  tighten  nonmetallic,  threaded  fittings.  One  full 
turn  past  hand  tight  is  usually  enough  to  prevent  leakage. 
Teflon®  sealant  tape  is  provided  and  should  be  used  on  all 
threaded joints, including the spout. 

8. 

Check  hoses  for  weak  or  worn  conditions  before  each  use, 
making certain that all connections are secure. 

9. 

Periodically  inspect  pump  and  system  components.  Perform 
routine maintenance as required. 

10. 

Drain all liquids from the system before servicing. 

 

Any  pump  used  to  transfer  flammable liquids  must  be  stored  in a well-
ventilated area after use. 

 

PERSONAL SAFETY 

1. 

Wear safety glasses at all times when working with pump. 

2. 

Wear  a  face  shield,  proper  apparel  and  suitable  respiratory 
equipment when pumping hazardous chemicals. 

3. 

Keep  work  area  clean,  uncluttered,  and  properly  lighted. 
Replace all unused tools and equipment. 

4. 

Keep visitors at a safe distance from the work area. 

5. 

Make  workshop  childproof  with  padlocks,  master  switches, 
and by removing starter keys.  

 

Failure  to  follow  all  General  Safety  Information  can  result  in  a 
fatality, personal injury and/or property damage! 

 

ASSEMBLY AND INSTALLATION 

(Refer to Figure 1) 
1. 

Screw bung adapter (Ref. No. 3) into drum with threaded end 
down. 

2. 

Screw spout (Ref. No. 1) into pump casing (Ref. No. 2). 

3. 

Screw  suction  tube  (Ref.  No.  4)  into  base  of  pump  casing. 
Use Teflon® Sealant tape provided. 

4. 

Insert  pump  assembly  into  drum  through  bung  adapter  and 
tighten butterfly screw by hand. Do not use wrench or tool to 
tighten butterfly screw. 

 

Not for use with water or other liquids that may cause corrosion. 

 

OPERATION 

 
1. 

Rotate handle clockwise several times. 

2. 

For siphoning, set handle straight down. 

3. 

To stop siphoning, rotate handle ¼ turn. 

4. 

After  using  pump,  set  handle  straight  down.  Oil  will  drain 
back to container. 

5. 

To keep  unit  from sticking  or  rusting,  pour  in oil  and  turn  a 
few times. 

 
MAINTENANCE 

In  some  applications,  condensation  or  water  in  the  liquid  will  cause 
accumulation of residue buildup, liquid hardening, or jelling  inside the 
pump, which may cause the pump to stick. Pouring penetrating oil into 
the  pipe  opening  then  cranking  several  times  usually  will  free  the 
pump. 
 

Содержание 4820-95

Страница 1: ...mable and Combustible Code NFPA 56A Standard for use of Inhalation Anesthetics NFPA 77 Static Electricity NFPA 78 Lighting Protection Code NFPA 80 Standard for Fire Doors and Windows NFPA 251 Standard Method of Fire Test of Building Construction NFPA 704 Identification of the Fire Hazards of Materials other NFPA codes local codes and ordinances as needed in a particular application Any of the NFPA...

Страница 2: ...lated area after use PERSONAL SAFETY 1 Wear safety glasses at all times when working with pump 2 Wear a face shield proper apparel and suitable respiratory equipment when pumping hazardous chemicals 3 Keep work area clean uncluttered and properly lighted Replace all unused tools and equipment 4 Keep visitors at a safe distance from the work area 5 Make workshop childproof with padlocks master swit...

Страница 3: ... re tighten cover bolts 10 Damaged worn pump parts 10 Remove pump cover and inspect for broken pieces Components should have smooth finish no large grooves or voids Replace damaged parts Piston type pumps may include a poppet valve which is designed to prevent back flow If excessive leakage past valve is found replace valve some leakage is normal Handle difficult or impossible to move 1 Pump has n...

Страница 4: ...d Repair Parts Manual 4820 95 5540 95 x For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 2 Repair Parts Illustration ...

Страница 5: ...eplace Pump Replace Pump 1 5 Vane Kit Carbon 4820 010 90 5540 010 90 1 6 Lip Seal 4820 300 90 4820 300 90 1 7 O Ring Kit 2 4820 301 90 4820 301 90 1 8 Crank Arm with Handle 4820 100 90 4820 100 90 1 9 Fastener 11 10 Taper Pin N A N A 4 11 Bung Adapter C209 170 90 C209 170 90 1 includes Ref No 13 12 Shim Clip C209 100 00 C209 100 00 1 13 Butterfly Screw Incl w Ref 11 Incl w Ref 11 1 14 Spout 4820 1...

Страница 6: ...Specifications Information and Repair Parts Manual NOTES ...

Страница 7: ......

Страница 8: ...www amtpump com ...

Отзывы: