5.1.2 Incremental Mode
The incremental mode is used to set up a contactless encoder knob. In addition to the incremental
output, a push button output is available to integrate a contactless push-button.
Figure 4:
Using the board in incremental mode
Note:
The grid and grid offset must be configured.
Note:
To use the push-button functionality
6
AS5601 Configuration
All options to configure the AS5601 are shown below. To use the AS5601 in incremental mode for a
contactless rotary knob, the electrical signal must be aligned with the mechanical grid. As well the
push-button threshold must be configured for the mechanical setup.
6.1 Configuring the grid offset
An ideal mechanical grid and the electrical output are shown below in
The transition of electrical signal should ideally be in the middle between two mechanical positions.