Example:
In the following example the 1000 Hz band would be the most dominant, but since the weighting factor
was scaled to -40 dB the 300 Hz band becomes the most dominant. The threshold factor is set to 1
dB, therefore if the level of the 300 Hz band drops by 1 dB the next band will be the most dominant,
here this Is the 30 Hz band.
Figure 113:
Threshold and Weighting Factor Example
10.1.2
Selectable Presets
You can select, if the algorithm switches between 2, 3 or 4 presets. The Algorithm automatically
detects which frequency band is corresponding best to the filter that was tuned in each individual
preset.
10.1.3
APS and Manual Preset Switching
If you are using the APS-Algorithm it is not possible to switch through the different presets manually,
since the APS-Algorithm controls the Preset Management.
10.1.4
APS and Monitor Mode
It is not possible, to include a Monitor mode preset into the APS-Algorithm. To use the Monitor mode
preset, you have to deactivate the APS-Algorithm and after the Monitor mode was used the APS-