The pump draws fluid from the bottom side of the reservoir. The pump output is routed to the 
supply thermometer, which indicates the output temperature of the fluid. From the 
thermometer the fluid is plumbed to the fluid connection panel. This is the connection for the 
chamber supply line. The chamber return line attaches to the other connector on the fluid 
connections panel. This is routed to the return thermometer, and back to the top of the 
reservoir to complete the cycle.  

The fluid connection panel is factory fitted to the rear side of the unit. It is possible to move 
this connection to the front of the unit if desired. Remove front and rear side covers from the 
unit, and the top cover to gain access to the internal plumbing. Remove blank panel from 
front, remove fluid connection panel from rear and route hoses to front side of unit and install 
fluid connection panel. Install blank panel on rear, install covers to complete the change. 

The reservoir also contains the heater, temperature bulbs, and sight glass. The heater is an 
immersion type, 220 VAC 3000 watt. Only heat or cool can be selected and operated at one 
time, not both. 

 

ELECTRICAL SYSTEM 

4.4

The electrical system operates from 220 VAC, single phase, 50/60 Hz. The unit requires a 
15 amp fused circuit, preferably from a separate disconnect box located close to the system. 
The heater and pump have separate internal fuses. The heater is fused at 15 amp, and the 
pump at 5 amps.  

The unit is controlled by internal contactors for the switching of AC power. This also provides 
the facility to control the unit remotely. The power for the contactors is supplied via a small 
internal step down transformer that provides 24 VAC. There are three contactors; one for the 
refrigeration system, one for the heater and one for the pump. Control is via a front panel 
toggle switch that turns the unit on, activates the pump contactor. This same switch passes 
control to the remote control connector, and disables local control. The second switch 
selects heat or cool or neither. The heat position activates the heat circuit if the power switch 
is on. The cool position activates the cool contactor when the power switch is on.  

The cool circuit has a time delay, which controls the energizing of the compressor contactor. 
Upon first actuation the delay is from 0 to 10 seconds before the compressor will turn on. 
After the first actuation the delay is approximately 45 seconds, which allows time for the 
compressor pressure to bleed down. This prevents a locked rotor condition and nuisance 
blowing of fuses or circuit breakers. 

The remote control Model 9000-RCS has one switch that turns the unit on in either the heat 
or cool position. 

 

 

Содержание 9000-ECS

Страница 1: ...760 599 3857 Email sales amronintl com Web www amronintl com This manual and the information contained herein are provided for use as an operation and maintenance guide No license or rights to manufac...

Страница 2: ......

Страница 3: ...N 6 GENERAL 6 4 1 REFRIGERATION 6 4 2 FLUID SYSTEM 7 4 3 ELECTRICAL SYSTEM 8 4 4 5 INSTALLATION 9 LOCATION 9 5 1 ELECTRICAL 9 5 2 6 OPERATION 10 7 MAINTENANCE AND TROUBLESHOOTING 11 GENERAL 11 7 1 TRO...

Страница 4: ...i 9 PARTS LIST GENERAL 25 9000 ECS ENVIRONMENTAL CONDITIONING SYSTEMS 26 9 1 9000 400 RESERVOIR SUB ASSEMBLY 27 9 2 9000 500 ELECTRICAL SUB ASSEMBLY 28 9 3 AC 5C MD 230V CIRCULATING PUMP 1 8 HP 230V 2...

Страница 5: ...ts ranging in size from 54 inch through 72 inch diameters There are certain conditions where the heat load may exceed the capacity of the unit These conditions may occur when the chamber is being pres...

Страница 6: ...120 o C Accuracy 1 of Full Scale Refrigerant Compressor Sealed Unit Refrigerant Freon R 404A Protection Internal Thermal Overload Locked Rotor Current 45 Amps Nominal Current Draw 6 4 Amps Restart Int...

Страница 7: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 3 MODEL 9000 ECS 1 3...

Страница 8: ...4 2 OPTIONS Model 9000 RCS Remote control switch allows remote control of the Model 9000 ECS The 25 foot remote control cable connects to the remote control connector on the Model 9000 ECS and permit...

Страница 9: ...C RETURN THERMOMETER 3 4 Three inch dial dual scale thermometer reads fluid temperature returning to the system Temperature range 0 o to 250 o F 20 o to 120 o C FLUID LEVEL INDICATOR 3 5 Slight glass...

Страница 10: ...ts of a fluid system reservoir pump to store and circulate the water a refrigeration unit to cool the water a heater to heat the water and controls to select the mode of operation Internal temperature...

Страница 11: ...circuit achieves a balanced condition when the spring force of the expansion valve refrigerant pressure temperature and evaporator pressure temperature results in the proper flow of Freon achieving t...

Страница 12: ...ase 50 60 Hz The unit requires a 15 amp fused circuit preferably from a separate disconnect box located close to the system The heater and pump have separate internal fuses The heater is fused at 15 a...

Страница 13: ...t be connected via a quick disconnect box with 15 amp fuses Power requirements are 220 VAC 50 60 Hz single phase Voltage limits are 187 to 250 VAC this allows the unit to operate on either a 220 or 20...

Страница 14: ...there will be a delay of approximately 45 seconds before the compressor starts This allows the pressures within the compressor to bleed off permitting easier starting and eliminates nuisance blowing...

Страница 15: ...eservoir An easy way to adjust the controller is to note the present setting of the controller and the point at which the heater did shut off and adjust accordingly Example The unit shut off at 100 o...

Страница 16: ...Cause Unit does not cool Check Freon charge Unit does not run Check power to unit Unit does not run power OK Check fuses to pump Unit does not run power OK fuses OK Check for 24 VAC Unit will not hea...

Страница 17: ...following drawings illustrate the electrical and mechanical details of the External Conditioning System unit The drawings reference identifier numbers correspond to the parts list identifier numbers...

Страница 18: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 14 MODEL 9000 ECS SPECIFICATIONS 8 1...

Страница 19: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 15 CHAMBER CONDITIONING CONNECTION DIAGRAM 8 2...

Страница 20: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 16 9000 ECS BLOCK DIAGRAM 8 3...

Страница 21: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 17 ELECTRICAL SCHEMATIC 8 4...

Страница 22: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 18 REMOTE CONTROL WIRING DIAGRAM 8 5...

Страница 23: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 19 PARTS LOCATOR EXTERIOR 8 6...

Страница 24: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 20 PARTS LOCATOR FRONT VIEW 8 7...

Страница 25: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 21 PARTS LOCATOR REAR VIEW 8 8...

Страница 26: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 22 PARTS LOCATOR TOP VIEW 8 9...

Страница 27: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 23 PARTS LOCATOR ELECTRICAL CONTROL BOX 8 10...

Страница 28: ...MODEL 9000 ECS USER MANUAL 9000 ECS UM REV 4 0 24 PARTS LOCATOR CIRCULATING PUMP PN AC 5C MD 230V 8 11...

Страница 29: ...er Replacement Parts Contact Amron International Inc 1380 Aspen Way Vista California 92081 U S A Telephone 760 208 6500 Fax 760 599 3857 Email sales amronintl com Web www amronintl com When ordering r...

Страница 30: ...D 16 0512 100 Tubing Braid reinforced 3 4 I D NS 125HBL 10 8 Hose Barb to male pipe brass NS 125HBL 12 12 Hose Barb to male pipe brass 19 129HB 12 12 Hose Barb 90 elbow to male pipe 20 PTR B 1 X 3 4 P...

Страница 31: ...Union 5 8 Brass 42 ECEB4X1 5 Elect Conduit Ext Box 4 X 1 5 43 3219 Grommet 230 546 dia Hole NS ECNP1 2X4 Elect Conduit Nipple 1 2 X 4 NS ECEL1 2 Elect Conduit Ell 1 2M 1 2F 46 A19ABC 4 Thermostat 50 T...

Страница 32: ...ontactor DPDT 24 VAC 62 S84Z 401 Transformer 24 VAC 40VA NS 9000 021 Cover Junction Box 64 9000 019 Bracket Electrical Connection 55 9000 018 Plate Junction Box Mounting 65 SO 14 3 Cableso Type14 AWG3...

Страница 33: ...Cover 4 O ring Buna N 4A O Ring Vito 5 Ceramic Thrust Washer 7 Spindle 8 Impeller magnet Assembly 8A Impeller Magnet Assembly W Stainless Cover 8B Impeller Magnet Assembly W Bronze Bushing 8C Impeller...

Страница 34: ...ccident repair or alterations SERVICE POLICY For technical assistance or to request a repair please complete one of the following Amron Communicator Repair https www amronintl com communicator repair...

Отзывы: