AMR LS-3030 Скачать руководство пользователя страница 2

INSTALLATION

 

 

Step 1 

 

Select a suitable mounting location for the module.  The primary location is the tail pulley and the  

 

secondary location is the take-up pulley. 

 

Step 2

 

 

Weld or otherwise attach a piece of 1/2” keystock or a large nut to the roller edge as shown in  

               figure 1. 
 

Step 3

 

 

Using the clamp and bracket provided, position the module so that the pick-up-face is as close to the 

 

keystock as possible without touching to prevent damage and wear.  This distance should not 

 

exceed 3/8” or nuisance tripping may result.  Optimum distance is 1/4” .  An indication light is built 

 

into the rear of the module in order to check proper positioning and operation. 

 
 
 

Note: 

Little Speedy should be mounted between 1/8 and 3/8 from a moving target. The movement 

 

of the target across the magnetic field of the sensor will reflect the speed of the target you are  

              monitoring.  For example, if mounted on the tail pulley of a conveyor belt, as the spokes or even a       
 

welded bolt rotate past the speedy’s sensor it will monitor the rate at which it passes.  This makes it 

 

possible to monitor for low belt speed ( meaning excessive amount of material ) or high belt speed 

 

( meaning little to no material on the belt ).   

 
 
 
 

LS - 3030 “ Little Speedy “ 

Little Speedy 
mounting 1/8” to 3/8” from target 

Содержание LS-3030

Страница 1: ...RICAN MINE RESEARCH INC MODELS LS 3030 BELT SLIP SEQUENCE AND CONTROL INSTALLATION AND SETUP INSTRUCTIONS P N 180 0361 P O Box 234 Rocky Gap VA 24366 540 928 1712 Fax 540 928 1814 E Mail amrinc inetone net ...

Страница 2: ...um distance is 1 4 An indication light is built into the rear of the module in order to check proper positioning and operation Note Little Speedy should be mounted between 1 8 and 3 8 from a moving target The movement of the target across the magnetic field of the sensor will reflect the speed of the target you are monitoring For example if mounted on the tail pulley of a conveyor belt as the spok...

Страница 3: ... further assistance in using this feature SPAN LED ZERO Step 5 Now that the LS 3030 has been mounted it can be calibrated Connect the Multimeter in line with the neutral and set the meter to read mA With the belt off the multimeter should read 4 mA on the output If not locate the zero potentiometer Using screwdriver rotate the pot counterclockwise till the multimeter reads 4 mA Now that the Zero C...

Страница 4: ...or the off condition 7 Now measure the movement the Belt or Device move per minute in it s normal running condition Type that value in Calibrate Gain to Obtain and Select Calibrate Span and press Enter with the Belt or Device operating under the same condition as the measurement was taken 8 Now that the Little Speedy has been calibrated the limits can be set Select Return and press Enter Select Li...

Отзывы: