4
STEP 3
Remove the shorting jumper from the control wires (GREEN to RED). Start
the belt and observe the calibration light. It should be on solid (not
flickering). If not, you may need to re-adjust the speed adjustment or the
positioning of the module.
STEP 4
At the end of the module is a test switch that can be used to check that the
unit is functioning properly. This switch will short out the pick-up coil
thereby checking the entire circuitry. When you push the switch, the control
contacts should drop out and the belt should stop.
**
Note that whatever
delay you have set will be present in this test.