2
INSTALLATION
STEP 1
Select a suitable mounting location for the module. This should be as close
to the belt starter control box as possible to reduce the possibility of cable
damage.
STEP 2
Weld or otherwise attach a piece of ½” keystock or large nut to the roller
edge as shown in figure 1.
STEP 3
Using the clamp and bracket provided, position the module so that the
pickup face is as close to the keystock as possible without touching to
prevent wear. This distance should not exceed ½” or nuisance tripping may
result. Optimum distance is ¼”. An indicating light is built into the rear of
the module to check proper positioning and operation.
STEP 4
Route the cable back to the belt starter control box
.
STEP 5
Make electrical connections as follows:
*Input Power (220 VAC): these two connections require constant 220 VAC
(+15%, -30%) at 3VA to run the LS-3000-220 circuitry. These connections
are made to the BLACK and WHITE wires.
An in-line fuse holder, with a
250mA, 3AG fuse (AMR part number 270-0043) is provided, to be wired in
series with the Black wire. This fuse is used to protect the internal circuitry
of the module.