AMQ ACTIV-Pro3 Скачать руководство пользователя страница 4

ACTIV-PRO3  

ASSEMBLY GUIDE  |  4

amqsolutions.com

    

WARNING

SAFETY STATEMENT

RISK OF SERIOUS INJURY:

POTENTIAL FOR INJURY: 

The use of worksurfaces that do not comply with the AMQ defined criteria and limitations 

could cause personal injury or property damage due to pinch points, instability, or other problems .

POTENTIAL FOR NON-COMPLIANCE: 

The use of work surfaces that do not comply with AMQ criteria VOIDS any 

AMQ claims of compliance with ANSI/BIFMA, UL, LEED, or other applicable requirements . The use of non-AMQ work 
surfaces on AMQ adjustable-height bases may NOT be accepted as compliant to municipal electrical codes or OSHA 
federal workplace standards, because this use does not create an NRTL (UL, ETL, etc .) listed product . AMQ is not 
responsible for the ultimate determinations of compliance for height-adjustable bases with non-AMQ work surfaces .AMO 
assumes NO liability for lack of standards compliance in these instances .

WARRANTY RESTRICTIONS: 

The use of non-AMQ supplied work surfaces VOIDS all AMQ warranties, expressed or 

implied .

DISCLAIMER: 

The use of non-AMQ work surfaces is NOT recommended . Any use of a non-AMQ work surface 

requires additional investigation by the customer regarding the appropriateness for use . It is the sole responsibility of 
the customer to determine the suitability and safety of the selected work surface construction and attachment means . 
The following information is provided as a guideline, but does not address all potential issues . Customers should seek 
professional guidance as to the appropriateness of their chosen work surface .

MANDATORY REQUIREMENTS REGARDLESS OF WORK SURFACE MATERIAL OR CONSTRUCTION: 
FASTENERS: 

Adjustable-height bases include fasteners intended for use with AMQ work surfaces .

These fasteners may potentially also be suitable for work surfaces meeting the following criteria:

•  Medium-density or higher particleboard or fiberboard cores with High-pressure laminate (HPL), Lowpressure 

laminate (LPL) or veneer & backers

•  Thickness of  .984” (25 .0 mm) or greater
•  Fasteners located a minimum distance of  .984” (25 .0 mm) from any edge

Any other work surface construction will require different and/or additional fastening means and these means must be 
determined by the project’s designer, architect, or engineer . For example, solid-surface materials should use appropriate 
threaded inserts and corresponding fasteners or 
similar attachment means .
In all cases, all fastener locations provided in the 
base attachment features MUST be used (e .g . if 
attachment plate has 6 screw holes, all 6 holes 
must be used for attachment) .

FLAMMABILITY: 

Any worksurface or similar large 

part> 10ft” 2 must have a flame spread< 200 
and a smoke developed index < 450 when tested 
per UL 723 .

SHARP EDGES: 

All accessible edges of the 

work surface must meet 1439 test for sharp 
edges .

DIMENSIONAL LIMITATIONS:

•  Work surface depth not to exceed 

30”(762mm)

•  Longitudinal work surface position on base 

must be on centerline

•  Maximum work surface width may not 

exceed 72” (1828 .8 mm)

•  Work surface overhang (distance from side 

of support cantilever to edge of work surface) 
must be greater than  .75” (19mm) and may not exceed 1 .25” (32 mm)

FOLLOW ALL WARNINGS PROVIDED FOR BASE+ WORK SURFACE.

WORKSURFACE

OVERHANG

CL

+

WORKSURFACE

WIDTH

WORKSURFACE

DEPTH

Содержание ACTIV-Pro3

Страница 1: ...ACTIV Pro3 assembly guide ...

Страница 2: ...eet 11 Adjusting Stretcher Bars 12 Connecting Power 13 Connecting Worksurface 14 Program Height Memory Presets 15 120 16 Components 17 Leg Attachment 18 Attaching Stretcher Bar 19 Attaching Cantilevers Feet 21 Adjusting Stretcher Bars 22 Connecting Worksurface and Power 23 Program Height Memory Presets 24 ...

Страница 3: ...fore moving on castors 1 Adjust desk to lowest height 2 Verify path is clear of obstructions 3 Remove objects not attached to desk 4 Restrict monitor arms from moving outside desk perimeter This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received i...

Страница 4: ...the appropriateness of their chosen work surface MANDATORY REQUIREMENTS REGARDLESS OF WORK SURFACE MATERIAL OR CONSTRUCTION FASTENERS Adjustable height bases include fasteners intended for use with AMQ work surfaces These fasteners may potentially also be suitable for work surfaces meeting the following criteria Medium density or higher particleboard or fiberboard cores with High pressure laminate...

Страница 5: ...ngs have a polarized plug one blade is wider than the other like the plug illustrated in Figure 1 This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way INSTRUCTIONS FOR DOUBLE INSULATED PRODUCTS No grounding means is p...

Страница 6: ...ACTIV PRO3 90 ...

Страница 7: ...d leg x 2 center leg x 1 M10 x 8 M6 special x 8 wood screw x 23 M6 x 12 handset screw x 2 cable clips x 12 8mm 5mm allen keys 4mm screw caps x 8 stretcher bar end x 2 stretcher bar x 4 frame BL x 1 frame BR x 1 frame FL x 1 frame FR x 1 controller cable x 2 power cable handset x 1 power box x 1 90 mending plate x 2 ...

Страница 8: ...ons com PHASE 1 Leg Attachment Step 1 Identify center leg Step 2 Assemble center leg to center bracket with M6 screws 2 1 Front Right Back Right Front Left and Back Left are indicated on Center Bracket with the initials FR BR FL and BL 90 ...

Страница 9: ...ng Stretcher Bar 1 BL BR FL FR Step 1 Match up frames to center bracket lining up the holes to the degree that you are setting 90 or 120 Screw in with M6 screws 1 Note limit of stretch length and assemble base within that limitation maximum mounting distance 90 ...

Страница 10: ...2 Assemble stretcher bars into the frames Step 3 Complete connecting the stretcher bars and stretcher bar ends Assemble end legs to the stretcher bar ends using M6 special screws NOTE Trim caps will be attached in Phase 4 2 3 For 48 width worksurfaces do not install stretcher bars 90 ...

Страница 11: ...et Step 1 Plug cantilevers into the stretcher bar ends lining up holes Add screws M6 special Tighten using 4 allen key or a long extension angle tipped allen key to expedite the process 2 2 1 Step 2 Attach feet to legs with M10 screws NOTE Trim caps will be attached in Phase 4 90 ...

Страница 12: ...Bars Step 1 Adjust stretcher bar to desired length NOTE The worksurface should be center aligned with the cantilever depth and should have equal amount of overhang on each end Step 2 Place caps 90 Make sure the screw bracket stays in the center of the stretcher bars 1 1 2 1 1 ...

Страница 13: ...low 90 Facing Direction Connect each plugs according to the drawing Orientate yourself to the table assembly by facing as user to identify left and right motor Position handset wire into dedicated slot before screwing down base to worksurface Right Motor Left Motor Power Position wire into dedicated slots to keep them neat tidy before screwing down base to worksurface 1 ...

Страница 14: ...rksurface using wood screws Step 2 Attach the handset to desired location using handset screws count x2 Step 3 Tighten 4 factory inset screws to hold desired length in place Step 4 Attach Mending Plates Applicable to ACTIV Pro3 90 using 2 piece worksurface setup to the worksurface using wood screws NOTE 1 piece worksurface setup does not need mending plates 90 4 3 2 1 ...

Страница 15: ... 1 2 3 or 4 Step 2 To Test Programmed Height Use the up down arrows to adjust the table to a height other than the preset height Then push and hold the number you programmed to see if it automatically adjusts to the height programmed in Step 1 You may need to hold for 2 3 seconds to activate the base NOTE If it does not adjust to the programmed height repeat Step 1 followed by Step 2 AMQ 1 2 3 M 4...

Страница 16: ...ACTIV PRO3 120 ...

Страница 17: ...et x 1 end leg x 2 center leg x 1 M10 x 8 M6 special x 8 wood screw x 23 M6 x 12 handset screw x 2 cable clips x 12 8mm 5mm allen keys 4mm screw caps x 8 stretcher bar end x 2 stretcher bar x 4 frame BL x 1 frame BR x 1 frame FL x 1 frame FR x 1 controller cable x 2 power cable handset x 1 power box x 1 120 ...

Страница 18: ...ons com PHASE 1 Leg Attachment Step 1 Identify center leg Step 2 Assemble center leg to center bracket with M6 screws 2 1 Front Right Back Right Front Left and Back Left are indicated on Center Bracket with the initials FR BR FL and BL 120 ...

Страница 19: ...ng Stretcher Bar 1 BL BR FL FR Step 1 Match up frames to center bracket lining up the holes to the degree that you are setting 90 or 120 Screw in with M6 screws 1 Note limit of stretch length and assemble base within that limitation maximum mounting distance 120 ...

Страница 20: ...2 Assemble stretcher bars into the frames Step 3 Complete connecting the stretcher bars and stretcher bar ends Assemble end legs to the stretcher bar ends using M6 special screws NOTE Trim caps will be attached in Phase 4 2 3 For 48 width worksurfaces do not install stretcher bars 120 ...

Страница 21: ...t Step 1 Plug cantilevers into the stretcher bar ends lining up holes Add screws M6 special Tighten using 4 allen key or a long extension angle tipped allen key to expedite the process 2 2 1 Step 2 Attach feet to legs with M10 screws NOTE Trim caps will be attached in Phase 4 120 ...

Страница 22: ... PHASE 4 Adjusting Stretcher Bars Step 1 Adjust stretcher bar to desired length Step 2 Tighten 4 factory inset screws to hold desired length in place Step 3 Place caps Make sure the screw bracket stays in the center of the stretcher bars 3 2 1 120 ...

Страница 23: ... center aligned with the cantiliver depth and should have equal amount of overhang on each end Step 2 Attach the handset to desired location using handset screws count x2 Step 3 Plug in electrical according to the diagram at right Attach cable management clips if using Facing Direction Handset Power Connect each plugs according to the drawing Orientate yourself to the table assembly by facing as u...

Страница 24: ... 1 2 3 or 4 Step 2 To Test Programmed Height Use the up down arrows to adjust the table to a height other than the preset height Then push and hold the number you programmed to see if it automatically adjusts to the height programmed in Step 1 You may need to hold for 2 3 seconds to activate the base NOTE If it does not adjust to the programmed height repeat Step 1 followed by Step 2 AMQ 1 2 3 M 4...

Страница 25: ...Please contact cc amqsolutions com if you are missing any parts have difficulty with assembly or have any product related questions ...

Отзывы: