Copyright 2021 Ampt LLC.
All rights reserved.
36
String Optimizer V600-32 Platform
Installation Manual: 57070021-1 A
28 A models (V525 - V600)
Vxxx-32-28 Models
V525
V550
V575
V600
Model Number
31570032-0525
31570032-0550
31570032-0575
31570032-0600
Electrical
Input
Maximum voltage per input
V
600
600
600
600
Maximum current (Imp) per input
A
22.4
22.4
22.4
22.4
Maximum short-circuit
current (Isc) per input
A
24.4
24.4
24.4
24.4
MPP tracking voltage range
V
300 - 455
300 - 480
300 - 505
300 - 530
Startup voltage per input
V
390
390
390
390
Number of inputs
2
2
2
2
Output
Output voltage range
V
0 - 525
0 - 550
0 - 575
0 - 600
Output voltage at full power
V
455
480
505
530
Output voltage at zero power
V
525
550
575
600
Maximum output current
A
28
28
28
28
Maximum continuous output power
kWdc
12.6
13.3
14.0
14.7
Efficiency (max / CEC / Euro)
%
99.3 / 99.3 / 99.2
Mechanical
Input & output connector
MC4-Evo 2
Dimensions
18.35" x 8.66" x 3.94"
(466.1 mm x 220 mm x 100 mm)
Weight
17.8 lbs. (8.1 kg)
Ambient temperature
operating range
-40 °F to +122 °F
(-40 °C to +50 °C)
Cooling
Convection
Environmental
Environmental category
Outdoor
Pollution degree
2
Maximum operating altitude
9843 ft (3000 m)
Overvoltage category
OVII
Ingress protection
IP66 / 4X
General
Compliance
ETL to UL 1741;
IEC 61000-6-1, 61000-6-3, 62109; CE;
Giteki 2-1-19; FCC Part 15, class A
Follow Ampt design guidelines to identify possible derating at high ambient temperatures or altitudes.