16A Output Models
V1250-16
V1275-16
V1300-16
V1325-16
V1350-16
V1400-16
V1450-16
V1475-16
Model Number
31570021-
1250
31570021-
1275
31570021-
1300
31570021-
1325
31570021-
1350
31570021-
1400
31570021-
1450
31570021-
1475
Electrical
Input
Maximum voltage per input
1
V
1500
1500
1500
1500
1500
1500
1500
1500
Maximum current per input
2
A
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
MPP tracking voltage range
V
400-1300
400-1300
400-1300
400-1300
400-1300
400-1300
400-1300
400-1300
Startup voltage per input
V
510
510
510
510
510
510
510
510
Number of inputs
2
2
2
2
2
2
2
2
Output
Output voltage range
V
0-1250
0-1275
0-1300
0-1325
0-1350
0-1400
0-1450
0-1475
Maximum output current
A
16
16
16
16
16
16
16
16
Max continuous output power kWdc
18.5
18.9
19.3
19.7
20.1
20.9
21.6
22.0
Efficiency (max, CEC, Euro)
%
99.6 / 99.5 / 99.4
Mechanical
Input & output connector
Amphenol H4
Dimensions
13.31" x 8.66" x 3.94"
(338 mm x 220 mm x 100 mm)
Weight
11.6 lbs. (5.3 kg)
Ambient temperature operating range
-40 °F to +122 °F
(-40 °C to +50 °C)
Cooling
Convection
Environmental
Environmental category
Outdoor
Pollution degree
2
Maximum operating altitude
3
9843 ft (3000 m)
Overvoltage category
OVII
Ingress protection
IP66 / 4X
General
Maximum system voltage
1500 V
Compliance
ETL to UL 1741;
IEC 61000-6-1, 61000-6-3, 62109; CE;
Giteki 2-1-19; FCC Part 15, class A
1. Voc at coldest design temp. F
ollow Ampt’s design guidelines to determine the number of modules per input and max. system voltage.
2. Module Imp at standard test condition (STC) - irradiation level of 1000 W/m
2
at 25°C.
3. Optimizer derates above this altitude.