ELECTRICALSPECIFICATIONS
Accuracy is giveN as ± % of r the number of least significant digits at
23
o
C ± 5
o
C, with relative hunidity Less than 80% R.H.
Range
Resolution
Accuracy
Overload
Protection
400V
0.1V
1000v
1V
±(1% rdg + 3 dgt)
1000V
AC RMS
Range
Resolution
Accuracy
Overload
45Hz ~ 400 Hz
Protection
400V
0.1V
1000v
1V
±(1,5% rdg + 3 rdg)
1000V
AC RMS
c
DC VOLTAJE
c
AC Voltage
(TRUERMS: Froml 10% al 100% of range)
●
Input Impedance: 10M
Ω
// less than 100pF.
crest Factor: <3:1
●
Input Impedance: 10M
Ω
.
Range
Resolution
Accuracy
Overload
Protection
400V
0.1V
1000v
1V
±(1% rdg + 3 rdg)
1000 Voltios CA
Eficaces (RMS)
c
VOLTAGE ( 1ms PEAKHOLD)
SPECIFIED A/- 40 Digits for Changes >1ms in duration .
●
Input Impedance: 10M
Ω
.
48
Содержание ACDC-620T
Страница 12: ...11 Figure 2 LCD Display ...
Страница 22: ...Figure 7 Display of Dynamic Recording 21 1 Press for more than 1 second to enter Dynamic Recording ...
Страница 31: ...Figure 17 Measuring AC Current CORRECT INCORRECT 30 ...
Страница 33: ...Figure 18 Measuring AC Curreft 32 ...
Страница 35: ...Figure 19 Measuring AC Motor Curent 34 ...
Страница 37: ...Figure 20 Measuring Voltage 36 ...
Страница 39: ...Figura 21 Measuring Resistance and Continuity FUSE CARTRIDGE 38 ...
Страница 41: ...Figure 22 Surface Temperature Measurement 40 Press Shift ...
Страница 43: ...Figure 23 Measuring Temperature on Refrigeration System Contact where you want to measuring PRESS T 42 ...
Страница 45: ...Figure 24 CAPACITANCEMEASUREMENTS 44 Negro Rojo ...
Страница 63: ...62 Figure 26 step 1 of Battery replacement Pull up slightly ...
Страница 64: ...63 Figure 27 Step 2 of Battery Replacement Pull and move to right ...