Amphenol RJS-5ES Series Скачать руководство пользователя страница 4

Unmanaged Switch User Manual 

Page 4 of 13   

 

   Last Revised: 11-Jul-06 

Amphenol

 – 948, Promenade de l‘Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com

 

 

Section 2 

LED Indicators 

 

Overview 
 

These switches have communication LEDs for each port and a power LED. Refer to the 
pictures below for the typical location of these LEDs. The exact location of these LEDs may 
vary between the different models.  

 

 

 

 

 

 

RJS-5ES-1 

(5 port – all RJ45)

 

RJS-5ES-2 or -3 

( 5 ports including 1 fiber)

 

RJS-9ES-1 

(9 ports – all RJ45)

 

 

 

 

 

 

 

 

 

 

 

 

 

Power LED  

This LED will be on solid when proper power has been applied to the unit. 

 

 

ACT / LNK 
LEDs 

The activity (ACT) and link (LNK) indication is combined into one LED (labeled 
“ACT/LNK” or “A”) on these switches. There is one of these LEDs per port. 

  

OFF

 – This would indicate that there is not a proper Ethernet connection (Link) between the 

port and another Ethernet device. Make sure the proper cable type is in use and that it has 
been plugged securely into the ports at both ends. See section 5 for proper Ethernet cabling. 

 

ON Solid (not flashing)

 – This would indicate that there is a proper Ethernet connection 

(Link) between the port and another Ethernet device, but no communications activity is 
detected. 

 

Flashing

 – This would indicate that there is a proper Ethernet connection (Link) between 

the port and another Ethernet device, and that there is communications activity. 

 

 

10 / 100 
LEDs 

This LED indicates what speed of communications is detected on the port. There is one of 
these LEDs per RJ45 port and it is labeled “S”. (The fiber optic port does not have one of 
these LEDs because its speed is fixed at 100 Mbps.) (Mbps = Megabits per Second) 

 

OFF

 – A 10 Mbps (10BaseT) connection is detected.

 

ON

 – A 100 Mbps (100BaseTx) connection is detected. 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание RJS-5ES Series

Страница 1: ...ing Page 6 Section 5 Ethernet Wiring Page 7 Section 6 Switching Features Page 9 Section 7 Technical Specifications Page 11 Section 8 Service Information Page 13 Applicable standards and certifications...

Страница 2: ...d state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Amphenol disclaims any responsibility for damages either direc...

Страница 3: ...Performance Specifications These general specifications apply to these switches Refer to Section 7 for complete technical specifications Ports models vary 10 100BaseT x Shielded RJ45 100BaseFX SC or...

Страница 4: ...roper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 fo...

Страница 5: ...iber 8 or 9 Copper Ports RJ45 0 275 0 70 cm 3 17 8 05 cm 2 935 7 45 cm ET GT 9ES Series Front View 4 75 12 07 cm 4 475 11 37 cm DIN EN 50022 not included 0 17 0 43 clear for 8 screw SC Fiber ST Fiber...

Страница 6: ...to terminals 2 and 3 Optionally on the 5ES models a backup power supply may be connected Refer to the wiring diagram below Terminal 1 should be tied to panel or chassis ground P1 P2 VDC Supplies To P...

Страница 7: ...for More Usage Ideas Note All 5 ports on the 5 port switch and ports 1 8 on the 9 port switch support auto speed duplex detection auto mdi mdix corssover and auto polarity Port 9 is an uplink port and...

Страница 8: ...rts support a maximum segment length of 2 km Singlemode ports support a maximum segment length of 15 km 40 km long haul models or even more contact Amphenol Each fiber optic port on the switch is comp...

Страница 9: ...t on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port...

Страница 10: ...s defined by IEEE 802 3 will be dropped This includes short frames long frames CRC error frames and alignment error frames IEEE 802 3 compliant The Amphenol Industrial Ethernet Switch strictly abides...

Страница 11: ...ed Max cable distance 100 meters Multimode Fiber Port 100BaseFX Fiber port mode Multimode Fiber port connector Duplex SC or ST Optimal fiber cable 50 125 62 5 125 m Center wavelength 1300 nm TX output...

Страница 12: ...d full duplex Environmental Required supply voltage 10 30 VDC Power consumption typical Max 8 Watts Note Power consumption varies on speed and amount of activity of each port 5ES 1 4 0 Watts 5ES 2 3 5...

Страница 13: ...ed under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on th...

Отзывы: