Amphenol RJS-5ES Series Скачать руководство пользователя страница 12

Unmanaged Switch User Manual 

Page 12 of 13  

 

   Last Revised: 11-Jul-06 

Amphenol

 – 948, Promenade de l‘Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com

 

 
 

General: 

Operation 

Unmanaged, Store and forward, non-blocking 

Compliance IEEE 

802.3 (10BaseT), 802.3u (100BaseTX), 802.3x (Flow Control) 

Latency (typical) 

5 usec (time to route a message from one port to another internal to switch) 

Memory bandwidth 

3.2 Gbps 

MAC addresses 

1K (1024) 

Address learning 

Automatic 

Address aging 

Remove old address after 300s 

Address migration 

Automatic 

Back pressure 

Automatic for half-duplex 

Buffer memory 

64KB (5ES models) or 128KB (9ES models) 

Buffers per port & buffer size 

Automatic and dynamic 

Illegal frames 

Dropped per 802.3 

Flow control 

Yes, for half and full duplex 

 

Environmental: 

Required supply voltage 

10 – 30 VDC 

Power consumption (typical); 
(Max. 8 Watts) 
(Note: Power consumption 
varies on speed and amount of 
activity of each port.) 

5ES-1: 4.0 Watts 

5ES-2/3: 5.0 Watts 
5ES-4/5: 6.0 Watts 

9ES-1: 6.0 Watts 

9ES-2/3: 7.0 Watts 

Power saving 

Automatic 

Max. screw terminal torque 
and wire gauge 

3.48 in-lbs (0.4 Nm), 14 AWG 

Operating temp. range 

-40 to 85 °C 

Storage temp. range 

-40 to 85 °C 

Humidity  

5 to 95 % (non-condensing) 

Flammability 

UL 94V-0 materials 

Electrical safety 

UL508, CSA C22/14; EN61010-1 (IEC1010), CE 

EMI emissions 

FCC part 15, ICES 003, EN55022; Class B; CE 

EMC immunity and surge 
withstand 

EN61326-1 (EN61000-4-2, 3, 4, 5, 6), IEEE-472 (ANSI C37.90), CE 

Vibration IEC68-2-6 
Hazardous locations 

UL1604, CSA C22.2/213 (Class 1, Div. 2), Cenelec EN50021 (Zone 2) 

Marine and offshore 

DNV tested 

Dimensions 

See mechanical diagrams 

Mounting 

DIN rail or panel direct 

 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание RJS-5ES Series

Страница 1: ...ing Page 6 Section 5 Ethernet Wiring Page 7 Section 6 Switching Features Page 9 Section 7 Technical Specifications Page 11 Section 8 Service Information Page 13 Applicable standards and certifications...

Страница 2: ...d state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Amphenol disclaims any responsibility for damages either direc...

Страница 3: ...Performance Specifications These general specifications apply to these switches Refer to Section 7 for complete technical specifications Ports models vary 10 100BaseT x Shielded RJ45 100BaseFX SC or...

Страница 4: ...roper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 fo...

Страница 5: ...iber 8 or 9 Copper Ports RJ45 0 275 0 70 cm 3 17 8 05 cm 2 935 7 45 cm ET GT 9ES Series Front View 4 75 12 07 cm 4 475 11 37 cm DIN EN 50022 not included 0 17 0 43 clear for 8 screw SC Fiber ST Fiber...

Страница 6: ...to terminals 2 and 3 Optionally on the 5ES models a backup power supply may be connected Refer to the wiring diagram below Terminal 1 should be tied to panel or chassis ground P1 P2 VDC Supplies To P...

Страница 7: ...for More Usage Ideas Note All 5 ports on the 5 port switch and ports 1 8 on the 9 port switch support auto speed duplex detection auto mdi mdix corssover and auto polarity Port 9 is an uplink port and...

Страница 8: ...rts support a maximum segment length of 2 km Singlemode ports support a maximum segment length of 15 km 40 km long haul models or even more contact Amphenol Each fiber optic port on the switch is comp...

Страница 9: ...t on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port...

Страница 10: ...s defined by IEEE 802 3 will be dropped This includes short frames long frames CRC error frames and alignment error frames IEEE 802 3 compliant The Amphenol Industrial Ethernet Switch strictly abides...

Страница 11: ...ed Max cable distance 100 meters Multimode Fiber Port 100BaseFX Fiber port mode Multimode Fiber port connector Duplex SC or ST Optimal fiber cable 50 125 62 5 125 m Center wavelength 1300 nm TX output...

Страница 12: ...d full duplex Environmental Required supply voltage 10 30 VDC Power consumption typical Max 8 Watts Note Power consumption varies on speed and amount of activity of each port 5ES 1 4 0 Watts 5ES 2 3 5...

Страница 13: ...ed under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on th...

Отзывы: