6
Part 1:
Package Contents
Part 2:
Receptacle Assembly
Receptacle connector for busbar type
Note: There will be no gasket provided when there is no sealing requirement
Gasket
1.
Tighten M4 nut onto Busbar (recommended torque is 1.2~1.5N.m)
1.
Pass receptacle through the hole of mounting panel
2.
Pass M4 bolt through copper busbar, washer and nut in proper order
3.
Tighten nut by tool
1.
Recommended M4 bolts refer to QB/T70.2-2015
2.
Recommended M4 Spring washer refer to BS 4464:1969(2004)
Mount Panel
Allen key
M4 Bolt
Busbar or other application
M4 Washer
M4 Nut
2.
Tighten receptacle onto the panel with M4 bolts (recommended torque is 0.4~0.7N.m)