25
240GT54/nrg240GT54
Amphenol Network Solutions
All rights reserved. 6.5.2020 150567
509.926.6000
— amphenol-ns.com.com
2.2.14 GMT Output Wiring (Connectorized Versions)
WARNING! Before connecting output power cables, make sure input power to the panel is turned off.
52. P24 output connectors are available in two sizes, #14-12 AWG and #12-10 AWG. Depending on the output
connector, crimp terminals onto one end of #14 to #10 AWG copper wires using Daniels M300BT crimp
tool or Burndy Y8MRB-1 crimp tool. (Work with one output wire at a time.)
53. Insert terminals into plug housing as shown in Fig. 2-16 and Fig. 2-17. The battery terminal goes in the
position on the connector with 2 locator tabs
and is marked “2”. The return terminal goes in the position on
the connector with 1 locator tab
and is marked “1”.
54. Insert retainer into plug housing as shown in Fig. 2-18.
Note:
If cables were placed in incorrect position, use a small pair of needle nose pliers or equivalent to
squeeze the retainer latch together. With latches released, grip the plug housing and pull on cables to remove
retainer.
Fig. 2-16: Insert Crimped Terminals
Fig. 2-17: Connector Front View
Fig. 2-18: Insert Retainer
1 Locator Tab: Return
2 Locator Tabs: Battery
Содержание 240GT54
Страница 1: ...240GT54 nrg240GT54 Installation Guide...