TROUBLESHOOTING

Ear symbol not illuminated

• Check that the power switch is toggled to the ON (I) position.
• Check fuse continuity. A 20mm fuse is incorporated into the AC POWER inlet. It is necessary 

to remove the power cord before extracting the fuse holder. Test the continuity of the fuse 

using a multimeter. A spare fuse is provided in the fuse holder. 

 

 

 

Any replacement fuse MUST be of the same rating and type as printed on the rear of 

the unit.

Ear symbol flashing continuously

Amplifier has failed self test and is in safe mode. Signal will not be fed into one or both loops. 

Switch the unit off, remove all connections except the loop and power connections, turn all front 

panel controls to minimum and switch back on. If the problem persists, contact Ampetronic for 

advice.

COMPRESSION LEDs not illuminating

Check input connections.
Ensure that the appropriate front panel control (INPUT1 or INPUT2) is turned up. Check there is 

sufficient signal level for the required input.

CURRENT LEDs not illuminating

There are many possible causes for this:

• Check the COMPRESSION LEDs are illuminating.
• Check that the CURRENT controls are turned up sufficiently.
• Check the LOOP, or TEMP LEDs are not illuminated.
• Ensure the Ear symbol is illuminated and not flashing.
• Check that the loop cables are connected, terminated correctly and inserted into the LOOP 

OUTPUT sockets.

• Check the loops are not open circuit, short circuit, or connected to earth (see instability or high 

frequency noise section of Troubleshooting)

• Switch the unit off and turn back on.

Note: You can listen to the actual loop signal by using a pair of headphones plugged into the 

monitor socket. Channel A = left, channel B = right

.

CLIP LED

(

s

)

 illuminated

Indicates that the output voltage is clipping. Occasional lighting of this indicator is normal on peaks 

of signal. 

• Turn down the CURRENT control on the channel(s) in question to avoid causing the output 

voltage to clip.

• Check the loop is not open circuit, short circuit, or connected to earth (see instability or high 

frequency noise section of Troubleshooting)

• Check the loop is within specified limits.

TEMP LED illuminated

Indicates that the internal heatsink is too hot. Loop current is not delivered to either channel.

• Ensure that the unit is installed in a location with sufficient ventilation

Содержание MLD5

Страница 1: ...MLD5 Installation Handbook www ampetronic com...

Страница 2: ......

Страница 3: ...r other apparatus that produces heat 6 WARNING THIS APPARATUS MUST BE EARTHED GROUNDED 7 Only power cords with the correct power connector may be used to maintain safety Cables incorporating the UK 13...

Страница 4: ...d inputs These can be configured for microphone or line inputs with individually selectable phantom and gain boost For more complex installations you may need ancillary equipment such as microphone pr...

Страница 5: ...LOSS CORREC TION MLC MLC LEVEL PHASE SHIFTER AGC DISPLAY RED L E D YELLOW L E D YELLOW L E D YELLOW L E D GREEN L E D GREEN L E D PHASE SWITCH 0 90 CHANNEL CURRENT LEVEL CHANNEL CURRENT LEVEL POWER AM...

Страница 6: ...y installed according to the Designing Induction Loops handbook or as per specific design instructions provided by Ampetronic As a result a target current should be known based on achieving acceptable...

Страница 7: ...il the target current is achieved as indicated by the CH B CURRENT LEDs Headphones can be used with the MONITOR socket to listen directly to the loop current NOTE channel A output appears in the left...

Страница 8: ...o hot Loop current is not delivered to either channel See toubleshooting for details MONITOR 3 5mm jack socket for use with stereo headphones to listen to the signal being delivered to the loop POWER...

Страница 9: ...DC OUTPUT 2 pin connection for ancillary units PHASE SHIFT SELECTOR Selectable 90 phase shift between outputs XLR INPUTS Socket for balanced MIC or LINE signals INPUT GAIN BOOST SELECTOR SWITCH Gain...

Страница 10: ...ble causes for this Check the COMPRESSION LEDs are illuminating Check that the CURRENT controls are turned up sufficiently Check the LOOP or TEMP LEDs are not illuminated Ensure the Ear symbol is illu...

Страница 11: ...istance loops can be encountered in a venue with a pre installed loop which was designed for use with an old loop driver which might be being replaced Before using this loop ensure that the existing l...

Страница 12: ...1 of Instability Failed AC power fuse in rear of unit Unplug the loop and AC power supply from amplifier and replace the failed fuse with the spare fuse in AC power input fuse tray Reconnect the AC po...

Страница 13: ...le circuit Attack decay 14 5 10 7 5 10 0 2 22 100 to 5000 4 7 1 24 17 9 6 4 13 0 2 22 100 to 5000 4 7 1 45 32 13 9 2 19 0 2 24 100 to 5000 4 7 1 V A A Hz ms s STATUS SOCKET 2 pin 5mm pitch 90 header T...

Страница 14: ...35 20 90 IP20 0 35 20 90 C WARRANTY This product carries a five year parts and labour warranty from date of shipment from Ampetronic To qualify for the five year warranty the product must be register...

Страница 15: ...INSTALLATION NOTES Ampetronic MLD5 Installation Handbook Page 13...

Страница 16: ...Contents Copyright Ampetronic Ltd 2013 All rights reserved UP17601 4...

Отзывы: