Connecting to Speaker Zone Selector
Use Cat5 cable
provided for
triggering port
connection
To external
volume
controllers
for
emergency
overriding
amplifier input /
speaker output
amplifier input / speaker output
24V
DC
24V
DC
PR link if more than one zone selectors are
installed
Zone 1 to 6
Zone 7 to 12
Zone 13 to 18
Zone 19 to 24
PIN CONFIGURATIONS :
Rear section of
TD6240
Triggering Ports
Cat5e Cable
with RJ45 Jack
Pin 8
Pin 1
Pin 1
Do not interchange wire
position between two jacks
when crimping.
IMPORTANT NOTICE :
Always check pin compatibility between TD6240
and Zone Selectors as earlier versions may not
work properly with the upgraded models.
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
Remote select port from ZS5601 can be plugged
to any of the port at TD6240.
(Only applicable to new version of ZS5601 only)
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
COM
24V
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
PAGE 6
TD6240 | PAGING MICROPHONE DATA DECODER