background image

Connecting to Speaker Zone Selector

Use Cat5 cable 

provided for 

triggering port 

connection

To external 

volume

controllers

for

emergency

overriding

amplifier input / 

speaker output

amplifier input / speaker output

24V

DC

24V

DC

PR link if more than one zone selectors are 

installed

Zone 1 to 6

Zone 7 to 12

Zone 13 to 18

Zone 19 to 24

PIN CONFIGURATIONS :

Rear section of

TD6240

Triggering Ports

Cat5e Cable 

with RJ45 Jack

Pin 8

Pin 1

Pin 1

Do not interchange wire 

position between two jacks 

when crimping.

IMPORTANT NOTICE :

Always check pin compatibility between TD6240 

and Zone Selectors as earlier versions may not 

work properly with the upgraded models.

P IN  8 -COM

P IN  7 -24V

P IN  6 -Z 6

P IN  5 -Z 5

P IN  4 -Z 4

P IN  3 -Z 3

P IN  2 -Z 2

P IN  1 -Z 1

Remote select port from ZS5601 can be plugged 

to any of the port at TD6240.

(Only applicable to new version of ZS5601 only)

P IN  8 -COM

P IN  7 -24V

P IN  6 -Z 6

P IN  5 -Z 5

P IN  4 -Z 4

P IN  3 -Z 3

P IN  2 -Z 2

P IN  1 -Z 1

COM

24V

P IN  8 -COM

P IN  7 -24V

P IN  6 -Z 6

P IN  5 -Z 5

P IN  4 -Z 4

P IN  3 -Z 3

P IN  2 -Z 2

P IN  1 -Z 1

PAGE 6

TD6240 | PAGING MICROPHONE DATA DECODER

Содержание TD6240

Страница 1: ...vor to make products with contemporary needs and yet expandable for future upgrades We are sure you make the right decision to choose Amperes which is not only offering the product that meets your bud...

Страница 2: ...c to be terminated at either one of the ports A mix priority setting in a circuit can also be connected to a single port 4 OUTPUT LEVEL SELECTOR Output level from the decoder can be set to Mic or Line...

Страница 3: ...MAX AUX SIG IN a m pe re s MX 2 1 2 2 O I MENU a m pe re s O I POWER QP2500 UP DOWN 500W 100V LINE POWER AMPLIFIER Cat5 multicore cable for zone triggering Preamplifier Mixer 7 UNIT ADDRESS DIP SWITC...

Страница 4: ...rallel connections for this port repeat for every zone Fr Amplifier To speakers or via VR LS4600 ZS5121 Z1 12 ZS5121 Z13 Z24 3 3 Set unit address each address represents one unit of decoder of 24 zone...

Страница 5: ...M S LOCAL MODE ON MASTER OFF SLAVE 24V DC 24V DC 24V DC 24V DC Cat5e EX2800 EX2800 EX2800 EX2800 TD6240 2 nos Paging Mic in same circuit Refer to note below PD2400 2800 PD2400 2800 PD2400 2800 PD2400...

Страница 6: ...Pin 1 Pin 1 Do not interchange wire position between two jacks when crimping IMPORTANT NOTICE Always check pin compatibility between TD6240 and Zone Selectors as earlier versions may not work properly...

Страница 7: ...3 Z49 72 Link data only Link data only Set the correct address for each decoder Max number of decoders that can cascaded is 8 inclusive of master Slave Slave 1 8 ON 2 ON 1 2 ON Operating voltage Cons...

Страница 8: ...the purchaser or the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certif...

Отзывы: