Connecting The Unit - Single Unit Installation
1
For Single unit paging mic, set priority level
to 0 (PD2800) or 00 (PD2400). Priority 1 is
highest.
Cat5e cable (supplied)
EX2800 External
Conn Unit
Rear view of PD2800
24V DC via
power adaptor
Remote location
2 pair screen cable
(audio and RS485 data)
1
Paging mic can be connected to any of the port regardless of the priority setting at the paging console.
IN
P
U
T
O
U
T
P
U
T
To mixer input ; select
either mic or line level,
balanced signal
2
2
Use this switch to select the audio output level ; mic or line level when connecting to pre-amplifier mixer
Remote triggerring using Cat5e / multicore
cable via RJ45 jack. (Cable provided )
24V DC
24V DC
24V DC
Fr. EP1200 for E/M 24V
overriding signal trig-
gering and ALL CALL
parallel connections
for this port
repeat for every zone
Fr.Amplifier
To speakers
(or via VR / LS4600)
ZS5121 (Z1-12)
ZS5121
(Z13 - Z24)
3
3
Set unit address ; each address represents one unit of decoder of 24 zones.
example : 10000 - Zone 1 to 24
01000 - Zone 25 to 48
4
4
Each connection port is for 6 zones triggering. Connect the correct port according to the zone numbering.
(See section : Connection to speaker zone selector)
RLY
TRIG
RLY
CON
ZS
PR
RLY
TRIG
RLY
CON
ZS
PR
Link to
Next ZS
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 1 2
P IN 5 -Z 1 1
P IN 4 -Z 1 0
P IN 3 -Z 9
P IN 2 -Z 8
P IN 1 -Z 7
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
P IN 8 -COM
P IN 7 -24V
P IN 6 -Z 1 2
P IN 5 -Z 1 1
P IN 4 -Z 1 0
P IN 3 -Z 9
P IN 2 -Z 8
P IN 1 -Z 7
DIP SWITCH 7
(TIMER SETTING)
ON = TIMER INFINITY
OFF = TIMER 5 MIN
M/S
LOCAL MODE
ON - MASTER
OFF - SLAVE
M/S
LOCAL MODE
ON - MASTER
OFF - SLAVE
PAGE 4
TD6240 | PAGING MICROPHONE DATA DECODER