background image

PAGE 4

PM1000 SERIES PAGING MICROPHONE

Connecting External Box to Zone Selector

Connecting to MX2322 Mixer Pre-Amplifier

PA

GING

 M

ICR

OP

HO

NE

PM

10

30

am

pe

res

CHIM

+ T

AL

K

PR

ESS

 TO 

TALK

L

R

L

R

CH9

CH10

LINE

LINE

MIC

( PM1010 / PM1030 )

REMOTE MIC

1

2

PHANTOM

POWER

CHANNEL

3

4

PHANTOM

POWER

CHANNEL

5

6

PHANTOM

POWER

CHANNEL

7

8

PHANTOM

POWER

CHANNEL

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

INPUT

+IN

GND

-IN

CH1

CH2

CH3

CH6

CH5

CH4

CH7

CH8

+

DC 24V

CH-B

+OUT

GND

-OU

T

CH-A

+OUT

GND

-OU

T

OUTPUT

+OUT

GND

+OUT

GND

+IN

GND

+IN

GND

CH-B

REC OUT

CH-A

WARNING !

TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

RISK OF ELECTRICAL SHOCK

DO NOT OPEN

CAUTION

CH12

PRIORITY

CH11

4)  GND

3)  NC

2)  COM

1)  NO

8)  +AUDIO

7)  GND

6)  -AUDIO

5)  +24V

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

500mA

RJ45 PIN CONFIGURATION:

AMPERES ELECTRONICS

amperes

R

MODEL : MX2322

PRE AMPLIFIER MIXER

MADE IN MALAYSIA

SER.

AC220-240V     50/60Hz 12W

AC220-240V     50/60Hz

FUSE: 500mA

PUBLIC ADDRESS POWER AMPLIFIER

SIGNAL -40 dB

SIGNAL -10 dB

POWER
PROTECT
CLIP

PA 2480

amperes

PM1030 can be connected to MX2322 mixer amplifier Remote Mic port without the External Box. With this connection, PM1030 shall has the 

highest priority over other sources. Take note that with above connection, MX2322 volume control does not amplify / attenuate the mic audio. The 

mic volume level is fully controlled by the mic volume knob.

cat5

POWER AMP 

(Direct connecting PM1030 / PM1010 to 

MX2322 without External Box)

PM1030

Balanced Audio

MX2322

24V DC via

power adaptor or

from Main Equipment rack

Optional connection for

triggering ALL CALL

24V DC

to VC / Patch 

overriding 

Relay Trigger at ZS Zone Selector shall 

activate ALL CALL as well as a dry contact.

ZS5122

PM1030 / PM1010 External Box 

To Pre-amplifier mixer / mixing amplifier or directly to 

amplifiers with line level output

Switch to select the required output level

  GND

+ AUDIO OUT

- AUDIO OUT

NO

COM

DRY CONTACT BALANCED OUTPUT 

INPUT

DC INPUT 

LINE LEVEL MIC LEVEL

RJ45 PIN CONFIGURATION

1)

NO

2)

COM

3)

NC

4)

GND

5)    +24V 6)    - AUDIO 7)      GND 8)    +AUDIO

ZONE S

E

LE

CTOR

ZS 5122

DC 24V

+ -

CONT

RELAY

RELAY

TRIG

PR

Z

REMOTE SELECT

A  B

RS485

1-Z1

2-Z2

3-Z3

4-Z4

5-Z5

6-Z6

7-24V

8-COM

UNIT ADD

ON

8

4

2

1

ZONE 1 TO 6

Quality Product From

AMPERES ELECTRONICS

Diagram above shows connection of PM1030 and ZS Zone Selectors ie. External Connector dry contact terminals to Zone Selector’s 

Relay Trigger terminals. Activation of PM1030 shall trigger All Call at zone selector as well as providing 24V DC output to override 

external volume controllers.

Содержание PM1010

Страница 1: ...simple press to talk without chime whereas its sibling PM1030 comes with pre announcement chime paging contact and chime volume controls which is designed for commercial applications Both models had b...

Страница 2: ...IO OUTPUT Output is balanced with either line or mic level which can be selected from this switch item 7 4 CHIME VOLUME CONTROLS PM1030 Individual control for chime and mic output level to suit the in...

Страница 3: ...R MIXER EP1200 POWER AMP 2 Core Dry Contact 2C Screen Audio PM1030 EXTERNAL BOX ALL CALL connection from PM1030 to Zone Selector is optional O I amperes MX2222 POWER OFF SELECT TUNER CD CASS OFF MASTE...

Страница 4: ...c port without the External Box With this connection PM1030 shall has the highest priority over other sources Take note that with above connection MX2322 volume control does not amplify attenuate the...

Страница 5: ...AKER WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION PM1030 Dry Contact to connect to MA2000 AC PR fo...

Страница 6: ...AMPLIFIERS ETC music audio Note By working with iPX5151 iPX5155 Paging Client PM1030 can broadcast paging via Ethernet to a remote location When activate paging PM1030 utilises its Dry Contact port to...

Страница 7: ...Weight 24V DC Cardioid condenser microphone 72 dB Omni directional Line level 300 ohm Mic level 50 ohm 200Hz 11kHz 3 dB 80 dB 3 dB Line output 1 2V rms balanced Mic output 70mV rms balanced 2m RJ45 c...

Страница 8: ...ormed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the prod...

Отзывы: