background image

Connecting the Unit

page 6

MR1300 MESSAGE RECORDER / PLAYER

Option B :
Using MR1300 for Emergency Announcement 

ZS5121
ZONE SELECTOR

MR1300
MESSAGE 
RECORDER / PLAYER

MX2222
MIXER

EP1200
EMERGENCY 
PAGING PANEL

MR1300 can be used as essential message source to PA system, linked to external activation device such as 

BAS system, emergency push button, etc.

1

0

0

V

AMP 4

Z

S

51

21

+

AMP 1

REMOTE SELECT

1

0

0

V

ZON2

1

0

0

V

C

O

M

1

0

0

V

1

0

0

V

C

O

M

C

O

M

ZON1

AMP 2

C

O

M

1

0

0

V

C

O

M

C

O

M

AMP 3

1

0

0

V

ZON3

C

O

M

ZON12

AMP 7

C

O

M

ZON6

C

O

M

C

O

M

ZON4

1

0

0

V

C

O

M

1

0

0

V

AMP 5

1

0

0

V

1

0

0

V

AMP 6

C

O

M

ZON5

C

O

M

1

0

0

V

REMOTE SELECT

1

0

0

V

1

0

0

V

AMP10

ZON8

1

0

0

V

1

0

0

V

ZON7

C

O

M

C

O

M

C

O

M

AMP 8

1

0

0

V

1

0

0

V

1

0

0

V

C

O

M

C

O

M

C

O

M

AMP 9

ZON9

1

0

0

V

1

0

0

V

C

O

M

C

O

M

C

O

M

ZON10

AMP11

1

0

0

V

1

0

0

V

1

0

0

V

C

O

M

C

O

M

ZON11 AMP12

DC 24V

CON

RLY

TRIG

RLY

PR

ZS

Another Quality Product From

MAINS : 230V +/-10%

M

X

22

22

LINE OUT

AC 50 / 60HZ

BGM

REC

CHIME

MIXER

PRIORITY MUTE

CH.1 / 2 / EXT.IN

AUX

CD

MIN

MAX

CH6

CH4

CH5

CH3

24V DC

DC INPUT

OUTPUT

EXT IN

CASS

TUNER

CH2

CH1

E

P

12

00

MIN

MAX

MAX

MIN

Another Quality Product From

S/N :

INPUT LEVEL

SIREN

MESSAGE

MESSAGE

SIREN

MESSAGE IN

PRE IN

PRE OUT

REMOTE TRIGGER

M

R

13

00

DC 24V

+

Amplifiers input and output connections

Zone selector triggering connectors to TD zone decoder

24V relay contact to 

volume controllers for 

overriding

Switch or sensor for 

message activation

Gnd

Bal.audio out

Bal.audio out

Audio output to 

power amplifier

2C cable

2C cable

The dry contact at the MR1300 is used to trigger EP1200, thus overriding the normal audio source for priority 

paging. It is then also connected to the Emergency Relay trigger at the Zone Selector, providing a dry contact for 

connecting 24V DC to override external volume controllers

Triggering Pre Recorded Message via UART ( RS485 )

MR1300 allows remote message activation via RS485 throught the port available at the rear panel. This use this 

feature, please enquire from us for further technical details.

Upgrading of firmware is also made possible via the RS232 port. Any new firmware updates notification shall be 

posted from time to time.

See Note Below

NOTE :

By default, the mode of activation is momentarily. For this configuration, set it to momentarily, and the dry contact 

shall be closed for the duration of the playback. This shall perform bypass of mixer audio output at EP1200 until 

the message is stopped.

Содержание MR 1300

Страница 1: ...MESSAGE RECORDER PLAYER INSTRUCTION MANUAL MR 1300 VER 2 MAY 2012 MR 1300 amperes MSG 2 BACK EXIT STATUS...

Страница 2: ...ghout the years We had added enough functions and flexibilities over the operations for the requirement of PA installations and this product shall be able to cater for any size of installations Among...

Страница 3: ...TA PORT RS232 data port for interfacing to PC for firmward upgrades 10 SD CARD 11 LINE INPUTS 12 LINE OUTPUTS Unbalanced line output for message playback RCA jack for recording from external source wi...

Страница 4: ...M AX AUX SIG IN a m pe re s M X 2 2 2 2 a m pe re s O VER RIDE O VER RIDE M R 1 3 0 0 a m pe re s MSG 2 TEST M IC SIR EN ACTIVATE POW ER F I R E a m pe re s E P 1 2 0 0 MR1300 MESSAGE RECORDER PLAYER...

Страница 5: ...ORITY MUTE CH 1 2 EXT IN AUX CD MIN MAX CH6 CH4 CH5 CH3 24V DC DC INPUT OUTPUT EXT IN CASS TUNER CH2 CH1 PT1800 PROG TIMER MR1300 MESSAGE RECORDER PLAYER MX2222 MIXER EP1200 EMERGENCY PAGING PANEL Dry...

Страница 6: ...SSAGE SIREN MESSAGE IN PRE IN PRE OUT REMOTE TRIGGER MR 1300 DC 24V Amplifiers input and output connections Zone selector triggering connectors to TD zone decoder 24V relay contact to volume controlle...

Страница 7: ...e a latched contact for the duration of the event Example a fire sensor is activated and the BAS pick up the distress signal it then provides a close contact which is then required to mute normal BGM...

Страница 8: ...tem update and bootloading MR1300 MSG Rec Player 1 AUDIO Menu Enter 2 MESSAGE 3 RECORD 4 SYSTEM To exit the system menu 5 SAVE EXIT Next 1 AUDIO Next Next Next Next Menu Enter 1 1 VOLUME Menu Enter 1...

Страница 9: ...splay shall return to Clear sub menu EXIT Exit to Message Sub Menu 2 M01 102 KB Menu Enter Use Next or Prev button to select the Message number 102 KB indicates the message s memory space 3 Record Sub...

Страница 10: ...se Next or Prev button to select Yes or No Details on upgrade to be available in near future Menu Enter 4 3 CLEAR MESSAGE Yes Use Next or Prev button to select Yes or No Press Menu to return to Sub Me...

Страница 11: ...k at rear of the unit To perform this option of recording 1 Select the approriate type of audio source either using dynamic microphone or line audio source 2 Press back exit button to select record mo...

Страница 12: ...a reasonable quality of audio output Slot for SD Card at the rear of the unit A few simple steps to save files into SD Card 1 Insert a SD card provided into Card Reader which is connected to your PC v...

Страница 13: ...for MSG01 to MSG08 are paralled Priority features shall ensure lower numbered unit has preference for playback Rear port activations GND BAS TIMER E M Activation via rear port can be from any external...

Страница 14: ...ellow Diagram 1 Diagram 2 Diagram 3 Diagram 4 Diagram 5 1 2 3 4 5 6 7 8 9 To perform firmware update 1 Link the MR1300 to PC as show in the Diagram 1 0 2 Run bootloader program at your PC and the wind...

Страница 15: ...ports via dry contact Front triggering 8 direct message playback key Indicators LED at switches LCD display Inputs Line input unbalanced via RCA jack Microphone input via front phone jack Input sensit...

Страница 16: ...e warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only for the described product and is not valid if modification...

Отзывы: