background image

Connecting PM1060 / 1120 Paging Microphone

PAGE 5

MA2000 SERIES | MIXER AMPLIFIER WITH 6 ZONE OUTPUT

Connecting EP1200 Emergency Paging Microphone

PM1060 / 1120 Paging Mic or other brands with negative trigger type can be used with MA2000 for zone triggering. Zone 

control from PM shall connect to Zone Trigger RJ45 port of MA while the audio ( line balanced ) shall go to Input 1 or 2. 

This is to enable muting of BGM whenever a paging is broadcasted.

2C Screen audio cable

Connect to either

Channel 1 or 2

for Priority

AMPERES EP1200 EMERGENCY PAGING MIC

OR

PT1801 mk II PROGRAM TIMER

OR

MR1301 MESSAGE PLAYER

If it is required to connect Amperes EP1200 Emergency paging mic ( or other emergency announcement such as 

MR1301 ) to MA2000 to make ALL CALL, follow the connection diagram below. Activation of EP1200 shall then turn ON 

all the zones ( All Call ) and bypass any other incoming music sources. Dry contact ( momentarily ) is required to turn 

ON all zones.

start of Pin 1

Pin 4   : Zone 4

Pin 8   : -VE

AMPERES ELECTRONICS

Another Quality Product From

S/N :

BALANCED

MIC OUT

MAX

MIN

PM1120

MAX

MIN

MIC

CHIME

PIN 1 to 6 : Z1 - Z6

PIN 7 : DC 24V

PIN 8 : GND

PIN 1 to 6 : Z7 - Z12

PIN 7 : DC 24V

PIN 8 : GND

TO ZS TRIGGER PORT

Cat 5e

0r 8 C for switching controls

2C Screen audio cable

PM1060 or PM1120 PAGING MICROPHONE

Link to next MA2000 if

need to expand 12 zone

paging system

controls

Balanced audio

Connect to either

Channel 1 or 2

for Priority

PIN CONFIGURATIONS FOR RJ45

This dot indicates

Pin 1   : Zone 1

Pin 2   : Zone 2

Pin 3   : Zone 3

Pin 5   : Zone 5

Pin 6   : Zone 6

Pin 7   : 24V DC

( PM1060 )

WARNING !

TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

RISK OF ELECTRICAL SHOCK

DO NOT OPEN

CAUTION

MUTE

PRIORITY MUTE

MAX

MIN

CH.1 / 2

LINE

MIC

LINE

MIC

1

2

PHANTOM

POWER

CHANNEL

3

4

PHANTOM

POWER

CHANNEL

LINE OUT

CH4

CH3

CH2

CH1

L

R

L

R

CH5

CH6

LINE

ANT

REMOTE SEL.

ALL

CALL

4)  Z4

3)  Z3

2)  Z2

1)  Z1

8)  GND

7)  +24V

6)  Z6

5)  Z5

RJ45 PIN CONFIGURATION:

MAX 20A

SPK5

SPK6

SPK4

SPK3

SPK2

SPK1

100V

COM

4 Ω 

OUTPUT

ADEQUATE VENTILATION

THIS EQUIPMENT REQUIRES

DO NOT BLOCK VENT

FUSE: 3A

AC220-240V     50/60Hz

AMPERES ELECTRONICS

amperes

R

Model : MA2036 P

MADE IN MALAYSIA

MIXER AMPLIFIER

AC220-240V     50/60Hz 450W

DC input 21-30V

Max. 20A

Rated output power 360W

24V DC

( PM1060 )

WARNING !

TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

RISK OF ELECTRICAL SHOCK

DO NOT OPEN

CAUTION

MUTE

PRIORITY MUTE

MAX

MIN

CH.1 / 2

LINE

MIC

LINE

MIC

1

2

PHANTOM

POWER

CHANNEL

3

4

PHANTOM

POWER

CHANNEL

LINE OUT

CH4

CH3

CH2

CH1

L

R

L

R

CH5

CH6

LINE

ANT

REMOTE SEL.

ALL

CALL

4)  Z4

3)  Z3

2)  Z2

1)  Z1

8)  GND

7)  +24V

6)  Z6

5)  Z5

RJ45 PIN CONFIGURATION:

MAX 20A

SPK5

SPK6

SPK4

SPK3

SPK2

SPK1

100V

COM

4 Ω 

OUTPUT

ADEQUATE VENTILATION

THIS EQUIPMENT REQUIRES

DO NOT BLOCK VENT

FUSE: 3A

AC220-240V     50/60Hz

AMPERES ELECTRONICS

amperes

R

Model : MA2036 P

MADE IN MALAYSIA

MIXER AMPLIFIER

AC220-240V     50/60Hz 450W

DC input 21-30V

Max. 20A

Rated output power 360W

24V DC

EMERGENCY PAGING PANEL

MESSAGE INPUT

PRE-AMP INPUT

MAIN OUTPUT

SIREN

MIC

1

8

BALANCE LINE LEVEL

VOLUME

+

DC 24V

POWER +

AUDIO + DATA

NO

A B

RS485

SIREN

TRIG

MESSAGE

TRIG

RELAY

CONT

EP 1200

2C cable

Содержание MA2006

Страница 1: ...n in order to capture the features available and how to suit your appli cations We assure you that you are getting a reliable product for usage in years to come O I amperes POWER 1 2 3 4 5 6 ALL OVERRIDE SPEAKER OUTPUT POWER BASS TREBLE SIG SIG SIG SIG CH2 CH1 SIG MIC SIG CH3 CH4 CH5 CH6 MASTER 360W 100V MIXER AMPLIFIER MA 2036P PLAYER PM1060 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO...

Страница 2: ...ed input signals prior to output Parts Identifications PAGE 2 MA2000 SERIES MIXER AMPLIFIER WITH 6 ZONE OUTPUT 9 MAIN OUTPUT VOLUME CONTROL Master volume control for mixed signal speaker and line outputs 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 O I amperes POWER 1 2 3 4 5 6 ALL OVERRIDE SPEAKER OUTPUT POWER BASS TREBLE SIG SIG SIG SIG CH2 CH1 SIG MIC SIG CH3 CH4 CH5 CH6 MASTER 360W...

Страница 3: ...alanced signal with XLR jack Use the mic line switch for correct signal level 6 zones of speaker lines can be connected via these Phoenix connectors 4 Ohm output is available but it is advised to use only single type of speakers For connection to EP1200 emergency paging mic for highest all call priority paging or other similar operation Stereo inputs for music sources for channel 5 and 6 Channel 1...

Страница 4: ...rs MAINS AC INPUT BATTERY INPUT 2 x 12V SLA Batteries PAGING MIC ZONE CTRL FM Antenna ANTENNA Cat5e or EP1200 Audio out to Ch 1 or 2 2C Screen Co ax 75 Ohm Cable Amplifier extension or to next mixing amplifier or to recording devices LINE OUT RCA AUDIO PLAYER IN MIC LINE INPUTS With Phantom Power On Unbalanced Line PC Audio Output Stereo PM1060 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK ...

Страница 5: ...one 1 Pin 2 Zone 2 Pin 3 Zone 3 Pin 5 Zone 5 Pin 6 Zone 6 Pin 7 24V DC PM1060 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION MUTE PRIORITY MUTE MAX MIN CH 1 2 LINE MIC LINE MIC 1 2 PHANTOM POWER CHANNEL 3 4 PHANTOM POWER CHANNEL LINE OUT CH4 CH3 CH2 CH1 L R L R CH5 CH6 LINE ANT REMOTE SEL ALL CALL 4...

Страница 6: ...MIN CH 1 2 LINE MIC LINE MIC 1 2 PHANTOM POWER CHANNEL 3 4 PHANTOM POWER CHANNEL LINE OUT CH4 CH3 CH2 CH1 L R L R CH5 CH6 LINE ANT REMOTE SEL ALL CALL 4 Z4 3 Z3 2 Z2 1 Z1 8 GND 7 24V 6 Z6 5 Z5 RJ45 PIN CONFIGURATION MAX 20A SPK5 SPK6 SPK4 SPK3 SPK2 SPK1 100V COM 4 Ω OUTPUT ADEQUATE VENTILATION THIS EQUIPMENT REQUIRES DO NOT BLOCK VENT FUSE 3A AC220 240V 50 60Hz AMPERES ELECTRONICS amperes R Model ...

Страница 7: ...CED SPARE PIN 3 TIP VE HOT SIGNAL RING VE COLD SLEEVE GROUND SCREEN 1 2 3 1 2 3 MUTE PRIORITY MUTE MAX MIN CH 1 2 CH1 No Mute Totally Mute Priority Channel Muting Ducking Channel 1 and 2 are priority channels that can mute other channels except audio from Paging Mic The mixing level can be adjusted to totally mix or total mute When both signals are present at Ch 1 and 2 they shall mix while muting...

Страница 8: ... while the bottom one shall skip to the next song and to increase the song volume Press this button to play or to pause The menu at the display would switch between RADIO USB SD BLUETOOTH RADIO Insert a SD Card or USB into the slot and the unit shall automatically enter the playing mode Next Prev Volume Button Play Pause Button Mode Button OFF ON OFF ON Button Individual power OFF ON for each modu...

Страница 9: ... On MA2000P series media player press MODE button until bLUE show up on the LED display indicates that the player is now in Bluetooth reception mode 2 On a Bluetooth transmission device turn On the Bluetooth mode It will start searching for active reception device around the area Figure on the left shows a mobile phone running on Android detected a device named ZTV CT02CA which is the MA2000P play...

Страница 10: ...de it is for searching stations 5 Play Pause Button Press this button to switch between Play and Pause 6 EQ Press this button to switch EQ modes Jazz Pop etc 7 VOL Press this button to increase or decrease volume level 8 CLOCK Press this button to switch to clock mode 9 RPT During playback press RPT button briefly to play the current track repeatedly and the LCD will display ONE Press RPT button t...

Страница 11: ...200 mm Without mounting bracket 4 6 kg 4 75 kg P Version 50Vrms 6 Selectable Output Zones Thermal Short Circuit AC DC Fuse Power Signal Indicator for Each Channel Output Signal Level 45 C Thermostat Automatic Fan Control 68 dB Bass 100Hz Treble 10kHz 15 dB 120 20 kHz 3dB 0dBu Balanced Line 220 240VAC or 22 30VDC Balanced MIC Input with 12VPhantom Power 10k Ohm Adjustable Mute Priority Balanced Lin...

Страница 12: ... out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufacturing defects and is valid for...

Отзывы: