MxP 2188

MULTIPLE INPUT SOURCES

MxP2188

DP2406

SPEAKER

Unit Installation

Application Schematic

HOT AIR

COOL AIR

COOL AIR

Rear View DP2406

DP 2406

3

4

PUBLIC ADDRESS POWER AMPLIFIER

        2 x 120W POWER AMPLIFIER

CH 1

CH 1

CH 2

CH 2

CH 3

CH 3

CH 4

CH 4

PAGE 4

AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER

The above diagram depicts the air flow pattern for amplifier cooling system. Cool air is pulled from the side vent holes and 

warm air shall be dissipated via the continous rotating fan.

Please ensure these vent holes are not blocked in order to keep the operating temperature at optimum. Allow a breathing 

space of 100 mm for each vent outlet.

For installation in rack, we recommend that internal rack ventilation fans are installed, one for cool air intake and the other 

for heat dissipation.

The optimum operating temperature of the unit shall be kept at approximately 40 degree Celsius.

Содержание DP2406

Страница 1: ...various advantages over conventional circuitries among them are the higher amplification efficiency thus emitting lesser heat and current draw flatter frequency response and able to withstand higher...

Страница 2: ...be supplied directly from the uninterrupted power source ie Back up batteries Alternatively connect it to regulated power supply unit which is in turned has back up supply 5 SPEAKER OUTPUT TERMINAL C...

Страница 3: ...for parallel linkage to the next unit 7 VOLUME KNOB CHANNEL 2 Output volume is adjustable from 15 dB to 0 dB 10 VOLUME KNOB CHANNEL 1 Output volume is adjustable from 15 dB to 0 dB 8 RESET BUTTON CHA...

Страница 4: ...ern for amplifier cooling system Cool air is pulled from the side vent holes and warm air shall be dissipated via the continous rotating fan Please ensure these vent holes are not blocked in order to...

Страница 5: ...tions Normal Applications CD1001 EP1200A MX2222 AC 230V 50 60HZ DC 24V 5 TIME OUT 5 MIN LINE MIC OUTPUT MASTER SLAVE 0 L S M M TD6080 SPEAKERS ZONE OUTPUT ZONE 1 ZONE 8 DA2208 PD1240 DP2406 DP2406 AMP...

Страница 6: ...INPUT CHANNEL 3 G OUTPUT INPUT CHANNEL 2 G OUTPUT INPUT CHANNEL 1 STANDBY G G OUTPUT INPUT OUTPUT OPEN LINK LINK SIGNAL OPEN LINK LINK SIGNAL OPEN LINK LINK SIGNAL OPEN LINK LINK SIGNAL OPEN LINK LINK...

Страница 7: ...Voltage Current Consumption Current Load Standby Input Input Sensitivity Outputs Frequency response Protection Indicator Cooling system Dimension WxHxD Weight 4 x 60W 100V line 230 240V ac 24V DC 1 4...

Страница 8: ...e dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only...

Отзывы: