TECHNICAL SPECIFICATIONS
Operating voltage
Power consumption
Input signal
Input impedance
Audio output gain
Pilot tone interval
Pilot tone frequency
Detection line
Detection level
Failure detection time
Failure recovery time
Zone load rating
Status indication LED
Changeover alert
Changeover section
Dimensions ( WxhXD )
Weight
24V DC ; 1A
7.2 W
6 Ch balanced line signal
10 K Ohm
Unity
10 seconds / channel
20 KHz ( +/- 5% )
70 / 100 V line
50 V rms min
10 - 25 seconds
20 seconds max
400W / 100V line
Normal ; Fault ; Changeover
Buzzer with switch
Input and output simultaneously
482 x 88 x 150 mm
3 kg
SUMMARY OF FEATURES
Cater for 6 duty and 1 standby and expandable to allow a standby pack to serve larger quantity of duty
amplifiers
Built in Pilot Tone generator which transmit at interval and senses at sequence to protect the power
amplifiers
Overloading protection by allowing only a single take over
Prioritised changeover which higher numbered amplifier shall be preferred for take over in the event
more than two units are down
Shorter fault detection time from 10 to 25 seconds
Changeover at input and output section simultaneously ; thus suitable for matrix system installations or
uninterrupted paging setup.
Input link switch ; making connection of sources easier than hardwired loopings which would make
interconnections look less messy.
Channel isolation switch for unused or unmonitored channels
Individual channel status indicators ; normal, fault and changeover
PAGE 11