VOICECOM USER MANUAL ISSUE 4
-30-
close the close relay output PSC1.
Line 1 Pre-start
Warning Tone
[ 0]
to
[ 7]
Sets the pre-start alarm tone for LINE 1.
There are 8 pre-start alarm tones available.
Line 1 Pre-Start
OK I Threshold
[ 30mA]
to
[180mA]
in 10mA steps
This sets the minimum current that must be
drawn by a VAA from its battery on LINE 1
in order for the VAA to confirm that it has
sounded the pre-start alarm. This can be set
to such a level as to indicate that one of the
VAA’s two speakers has failed. See the Pre-
Start Alarm chapter for more information
Line 1 Under
Voltage Alarm
Level
[ None]
This feature is not implemented in this
version of the VCA hardware and therefore
cannot be set.
Line 2 : Number of
VAA’s to be
Online
[ 1]
to
[31]
or
[None]
This is the number of VAA’s that are
connected to the LINE 2. This is the number
of VAAs that the VCA should be able to
communicate with. If no VAAs are
connected, then this is set to None.
Line 2 Service
Factor
[0]
to
[5]
This is the maximum number of VAAs on
LINE 2 that can fail to sound a pre-start
alarm and still allow the pre-start to be
successful. A successful pre-start alarm will
close the close relay output PSC1.
Line 2 Pre-start
Warning Tone
[ 0]
to
[ 7]
Sets the pre-start alarm tone for LINE 2.
There are 8 pre-start alarm tones available.
Line 2 Pre-start
OK Current
Threshold
[ 30mA]
to
[180mA]
in 10mA steps
This sets the minimum current that must be
drawn by a VAA from its battery on LINE 2
in order for the VAA to confirm that it has
sounded the pre-start alarm. This can be set
to such a level as to indicate that one of the
VAA’s two speakers has failed. See the Pre-
Start Alarm chapter for more information
Line 2 Under
Voltage Alarm
Level
[ None]
This feature is not implemented in this
version of the VCA hardware and therefore
cannot be set.
Modbus
Communication
Baud Rate and
Parity
[1200 Baud,Even/Odd/No
Par]
[2400 Baud,Even/Odd/No
Par]
[4800 Baud,Even/Odd/No
Par]
[9600 Baud,Even/Odd/No
Par]
[19k2 Baud,Even/Odd/No
Par]
This set the communication parameters for
the Modbus RS-485 port. There are 5 baud
rates and the parity can be set for each
baud rate.
Modbus
Communication
Slave Address
[ 1] to [31]
This sets the VCA’s Modbus slave address.
Содержание VAA
Страница 73: ...VOICECOM USER MANUAL ISSUE 4 77 APPENDIX G I S Approvals ...
Страница 74: ...VOICECOM USER MANUAL ISSUE 4 78 ...
Страница 75: ...VOICECOM USER MANUAL ISSUE 4 79 ...
Страница 76: ...VOICECOM USER MANUAL ISSUE 4 80 ...
Страница 77: ...VOICECOM USER MANUAL ISSUE 4 81 ...
Страница 78: ...VOICECOM USER MANUAL ISSUE 4 82 ...
Страница 79: ...VOICECOM USER MANUAL ISSUE 4 83 ...
Страница 80: ...VOICECOM USER MANUAL ISSUE 4 84 ...
Страница 81: ...VOICECOM USER MANUAL ISSUE 4 85 ...