AMP HHA1 Скачать руководство пользователя страница 14

AMN-H-D 

12 

 

 

8. 

MAINTENANCE INSTRUCTIONS 

8.1. 

Cleaning 

AMP Power Amplifiers should be periodically wiped off with a clean, damp cloth.  For more thorough 
cleaning, dampen a clean cloth with glass cleaner and wipe off unit.  Ensure units are completely 
disconnected from their power sources before cleaning. 
 

8.2. 

Troubleshooting  

To avoid poor performance, ensure all mating connectors are tightly fastened, clean, and have no pins 
bent or damaged. 
 
If poor or no operation is observed, ensure the external DC voltage supply is b11 and +16 Vdc 
with correct polarity.  All AMP Power Amplifiers have over-voltage and reverse polarity protection circuits.  
If the input voltage is over +16 Vdc, remove the DC Power Cable from the unit, reduce the DC voltage to 
b11 and +16 Vdc, and reconnect the DC Power.  If the input voltage is negative polarity, remove 
the DC Power Cable from the unit, reverse the connections between the DC voltage supply and DC 
Power Cable, and reconnect the DC Power Cable. 
 
If poor or no operation is still observed, verify that your enable pin (see Section 7.2) and power output 
level (see Section 7.3) are set properly for your Power Amplifier and that the output power of your 
transmitter matches the acceptable power input range for your Power Amplifier configuration. 
 
If these efforts fail, do not attempt to repair the unit.  Please contact AMP with a detailed description of the 
problem.  Depending on the nature of the problem, AMP may provide further troubleshooting assistance 
or advise the entire system be returned for repair and retest. 
 
Caution: Removal of the cover constitutes breaking the seal and VOIDS PRODUCT WARRANTY.  
 

8.3. 

Preparation for Reshipment 

If the power amplifier, and/or any other purchased item(s) are to be shipped to another location or 
returned for repair or realignment, use the original packaging or a sturdy box with sufficient protective 
material to avoid damage from movement or exposure during transit.  Remove all external connections 
(cables, antenna, etc.) prior to shipping. 
 

8.4. 

Returning an Item 

Please contact AMP customer service at (775) 345-9933 for a Return Authorization Number before 
returning an item.  The AMP ship-to address is listed below. When returning an item, always include a 
contact name and phone number and a detailed description of the problem with your shipment.  
 

Advanced Microwave Products 

8748 Technology Way 
Reno, NV 89521 
 

Содержание HHA1

Страница 1: ......

Страница 2: ...3 5 HSP1 List of Items Required 5 4 HSF1 Power Amplifier 6 4 1 HSF1 Specifications 6 4 2 HSF1 Mechanical Drawing and Connector Pin Outs 7 4 3 HSF1 List of Items Furnished 7 4 4 HSF1 Optional Accessori...

Страница 3: ...d connectors Compact package sizes provide versatility in unit placement and system applications AMP Power Amplifiers require no tuning or adjustments Power can be derived from batteries simple power...

Страница 4: ...AMN H D 2 2 HHA1 HIGH POWER AMPLIFIER 2 1 HHA1 Specifications...

Страница 5: ...RF50 SSS20 2 SMA SMA Coax for use with EST1 or PMT1 or CBLRF50 SSS30 3 SMA SMA Coax for use with VST1 PST1 or FMT1 2 4 HHA1 Optional Accessories WHSMDM9 SSLH0 MDM 9S Socket DC Power Cable SNK3535 S12B...

Страница 6: ...AMN H D 4 3 HSP1 POWER AMPLIFIER 3 1 HSP1 Specifications...

Страница 7: ...3 3 HSP1 List of Items Furnished 1 HSP1 Power Amplifier configured as ordered 1 CBLRF50 SSS10 1 SMA SMA Coax 3 4 HSP1 Optional Accessories SNK3520 S05B0 Heatsink 3 5 HSP1 List of Items Required Antenn...

Страница 8: ...AMN H D 6 4 HSF1 Power Amplifier 4 1 HSF1 Specifications...

Страница 9: ...Items Furnished 1 HSF1 Power Amplifier configured as ordered 1 WHSHSF1 S08S0 Power Mating Connector 1 CBLRF50 SSS10 1 SMA SMA Coax 4 4 HSF1 Optional Accessories SNK3520 S05B0 Heatsink 4 5 HSF1 List of...

Страница 10: ...ADIATION HAZARD In order to keep the RF Exposure within the FCC 1 1310 limit a safe personal distance from the antenna must be maintained according to the below tables The first table is for transmitt...

Страница 11: ...complete The HSP1 does not have a power connector but instead has flying leads Do not connect the DC power to the HSP1 leads Red lead positive DC input black lead negative DC input ground until all ot...

Страница 12: ...RF power output If included the power level is set using the yellow wire shown in Section 3 2 To set the amplifier to the higher output power level leave the yellow wire open or driven to 3 3 Vdc by...

Страница 13: ...head screws with lock washers Use of thermal grease such as Wakefield Engineering 120 Series Thermal Compound to improve thermal conduction between transmitter base plate and heat sinking surface wil...

Страница 14: ...vel see Section 7 3 are set properly for your Power Amplifier and that the output power of your transmitter matches the acceptable power input range for your Power Amplifier configuration If these eff...

Страница 15: ...ng damage Limitation of Warranty The above warranty does not apply to defects of or resulting from the following 1 End items included as part of a system but not designed by AMP are subject only to wa...

Отзывы: