6.5 CONTROL VALVE ACTUATOR
The control valve actuator has three positions, OPEN, OFF, and CLOSE. The control valve actuator includes a deadman safety feature
which returns the control valve actuator to the OFF position (neutral) when released. When the control valve is in the OFF position, the
tool movement stops, and holds position and load. The control valve actuator controls the motor and hydraulic pump. Electronics within
the tool prevent electrical overload during operation.
Verify operation of control valve actuator by checking to see it returns automatically to the neutral position when released.
7.0 OPERATION
7.1 BATTERY CHARGE STATUS
Check the battery charge status using the indicator lights on the battery by pushing the status button on the battery.
Figure 7.1
7.2 WHEN TO CHANGE THE BATTERY
ION tools keep power ON until turned off, or after 20 minutes of inactivity. The battery management system maintains power until the
battery is drained. Push the status button on the battery to check the battery status. The indicator light bars display the battery’s charge
status.
Change the battery if the battery no longer continuously operates the tool, there is one bar left on the battery charge indicator, or the
Status LED indicates “red” for low battery.
7.3 STORAGE RECOMMENDATIONS
1. The best storage place is cool and dry, away from direct sunlight and excess heat or cold.
2. For long storage, it is recommended to store a fully charged battery pack in a cool dry place out of the tool and charger for optimal
results.
3. If the tool is exposed to water, remove the battery. Allow the battery and tool to dry before storage or use.
7.4 STATUS LED
During tool operation, the brightness of the LED will adjust to indicate to the user the amount of power the tool is currently using to
operate. The brighter the LED the more power being applied to cutting or spreading. The LED is also used to communicate status of
important tool conditions to the operator. Error codes will not prevent the tool from operating. The codes are intended to alert the
operator of a potentially harmful condition.
LED COLOR
STATUS MESSAGE
Green
Battery Good
Red
Battery Low
Yellow
Tool in Error
• Temperature is over 113°F (45°C)
• Temperature is under 3°F (-16°C)
• Actuator ON, motor not running
• Actuator NOT ON, motor running
Flashing Red
Battery Fault