background image

©Copyright Amkus Rescue Systems, Inc. 2010-2020 

LAP-005 JUNE 22, 2020 Rev05

Important Safety Instructions

Safety

It is the responsibility of the user to insure that appropriate 

protective clothing and equipment are used to provide 

protection from those hazards to which personnel are 

exposed or could be exposed while working with this 
product.

 

Always wear appropriate apparel!

AMKUS equipment is manufactured with superior 

craftsmanship and quality that is backed by a factory 

warranty.  AMKUS cannot control how other manufacturers 

of rescue tools rate, test and warranty their equipment.  

Therefore, we do not recommend that tools other than 

AMKUS be connected to our equipment.  Mixing AMKUS 

equipment with another manufacturer’s equipment may 

cause operational problems, equipment failure or warranty 

claims to be denied.

Use only AMKUS supplied 

mineral base hydraulic 

fluid in all AMKUS equipment.

Training

This product is designed to be used by emergency services 

personnel to facilitate the extrication of victims from 

entrapment.  Its use should be limited to trained personnel 

only.  All personnel using this equipment are assumed to 

have completed a course of instruction that is acknowledged 

as being educationally sound by the local authority having 

jurisdiction over such training.  This document contains 

basic operating and maintenance instructions only.  

Getting Started

1. Connect the tool connection hoses to the hose lines from 

the AMKUS hydraulic power unit.  Please note that the 

male and female couplings on the hose lines leading from 

the power unit should be connected to the corresponding 

male and female couplings on the tool connection hoses.  

To connect the couplings, twist the sleeve on the female 

coupling so that the notch in the sleeve lines up with the 

pin.  Push the sleeve back so the pin fits into the notch.  

While holding the sleeve back, push the male coupling 

into the female coupling.  Release the sleeve; it will spring 

forward into place.  Twist the sleeve ¼ turn so that the pin 

no longer lines up with the notch.  Pull on the couplings to 

check that they are securely connected. 
2. Check the engine oil, engine fuel and hydraulic fluid 

levels.  Add as appropriate. 

Read and understand the 

engine owner’s manual 

before operating the engine!  Failure to do so 

could result in personal injury or equipment 

damage!

Set-Up Procedures

Normally, AMKUS equipment is prepared and serviced by 

your dealer prior to delivery.  If, however, you have decided 

to place the equipment into service yourself, please review 

the following instructions carefully.
1.  Remove equipment from the packing cartons and 

carefully inspect for damage.  Damage that occurs during 

shipment should be reported immediately to the carrier.
2.  The Briggs and Stratton

®

 

engine that powers your unit is 

shipped without engine oil.  Fill the engine crankcase with 

the proper oil as specified in the engine owner’s manual. 

3.  Next, remove the hydraulic fluid reservoir fill plug/vent 

cap.  Fill the hydraulic fluid reservoir with approximately 2.0 

gallons U.S. (7.6 liters) of AMKUS mineral base hydraulic 

fluid.  The fluid should reach a level that fills approximately

 

1

/

2

 of the sight gauge window.  Replace the fill plug/vent cap.

4.  Following the instructions in the engine owner’s 
manual, fill the engine fuel tank with the specified fuel.  

Avoid getting dirt or water in the fuel tank.  Never use stale 

or contaminated gasoline or an oil/gasoline 
mixture.
5.  This power unit may be supplied either with hydraulic 

hoses attached (pump hoses) or with couplings that require 

extension hoses.  If your unit is equipped with couplings, 

attach the extension hoses to the couplings on the power 

unit.  In either case, connect the male and female couplings 

on each of the hydraulic hose line sets, creating a loop.
6.  Follow the operating instructions in the engine owner’s 

manual for starting the engine.  Then operate the engine at 

full speed. 
7.  To purge air from the hydraulic hoses, charge each 

hose line by moving the knob on the corresponding selector 

valve to the pressure position (in line with the selected hose 

line) and allow the fluid to circulate through each hose line 

for at least one minute.  Move each selector valve back to 

the neutral position. 
8.  Check the level of the hydraulic fluid in the sight gauge.  

Add more fluid if necessary.  DO NOT OVERFILL. 
9.  Uncouple the male and female couplings on each 

hydraulic hose line set to open the loop that was created 

earlier.  The power unit is now ready to use. 

CAUTION

CAUTION

Содержание GB2S-XLO

Страница 1: ...Designation MTO DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with EN ISO 4871 Measured A weighted emission sound pressure level LpA ref 20µPa in decibels 88 2 Uncertainty KpA in decibels 1 5 Measured A weighted sound power level LWA ref 1 pW in decibels 100 2 Uncertainty KWA in decibels 1 5 Values determined according to Annex B of EN 13204 using the basic standards EN ISO 3744 and EN ...

Страница 2: ...l and hydraulic fluid levels Add as appropriate Read and understand the engine owner s manual before operating the engine Failure to do so could result in personal injury or equipment damage Set Up Procedures Normally AMKUS equipment is prepared and serviced by your dealer prior to delivery If however you have decided to place the equipment into service yourself please review the following instruc...

Страница 3: ... coupling Move the selector valve to charge the line to which the gauge is connected The nominal pressure of the system is 10 500 psi The pressure reading you receive should be between 10 000 psi and 11 000 psi If you have a reading outside of that range contact your local dealer or AMKUS Inc DO NOT ATTEMPT TO ADJUST THE PRESSURE RELIEF SETTING Routine Maintenance for Hoses After each use hoses sh...

Страница 4: ... while the couplings may be clean the dust caps will accumulate dirt during use Do not cover a clean coupling with a dirty dust cap GB2S XLO Power Unit Specifications Length 23 0 in 584 mm Width with one hose loop standard 19 0 in 483 mm Height 20 5 in 521 mm Weight Ready to use 109 6 lbs 50 kg Includes gas engine oil hydraulic fluid and couplings Rated Output Pressure 10 500 psi 724 bar Fluid Typ...

Отзывы: