2.0 SPECIFICATIONS

DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with EN ISO 4871

Measured A-weighted emission sound pressure level, L

pA

 (ref. 20μPa), in decibels: 88.2

Uncertainty, K

pA

, in decibels: 1.5

Measured A-weighted sound power level, L

WA

 (ref. 1 pW), in decibels: 100.2

Uncertainty, K

WA

, in decibels: 1.5

Values determined according to Annex B of EN 13204 using the basic standards
EN ISO 3744 and EN ISO 11201.

NOTICE

The sum of a measured noise emission value and its associated uncertainty represents an upper 

bound of the range of values which can occur in measurements.

Length

19.5” (495mm)

Width

15.0” (381mm)

Height

22.0” (559mm)

Weight (ready to use)

(Includes gas, engine oil, hydraulic fluid, couplings)

101 lbs (46kg)

Rated Output Pressure

10,500 psi (724 bar)

Fluid Type AMKUS MV-1 Mineral Based Hydraulic Fluid

(for equipment stored and operated in environments below 

freezing, use AMKUS MV-0 Mineral Based Hydraulic Fluid)

Hydraulic Fluid Reservoir Capacity

2.0 gal US (7.6 I)

Usable Hydraulic Fluid Capacity 

1.45 gal US (5.51 I)

Maximum Angle Of Inclination

20 degrees from horizontal

Safety Data Sheet (SDS) for AMKUS MV1 Hydraulic Fluid is available 

 

at AMKUS.com and CHEMTREC.com

3.0 SAFETY

It is the responsibility of the user to insure that appropriate protective clothing and equipment are used to provide protection from 

those hazards to which personnel are exposed or could be exposed while working with this product.

CAUTION

Always wear appropriate apparel.

AMKUS equipment is manufactured with superior craftsmanship and quality that is backed by a factory warranty. AMKUS cannot 

control how other manufacturers of rescue tools rate, test and warranty their equipment. Therefore, we do not recommend that tools 

other than AMKUS be connected to our equipment. Mixing AMKUS equipment with another manufacturer’s equipment may cause 

operational problems, equipment failure or warranty claims to be denied.

CAUTION

Use only AMKUS supplied mineral base hydraulic fluid in all AMKUS equipment.

4.0 TRAINING

This product is designed to be used by emergency services personnel to facilitate the extrication of victims from entrapment. Its use 

should be limited to trained personnel only. All personnel using this equipment are assumed to have completed a course of instruction 

acknowledged as being educationally sound by the local authority having jurisdiction over such training. This document contains 

basic operating and maintenance instructions only.

CAUTION

Read and understand the engine owner’s manual before operating the engine! Failure to do so 

could result in personal injury or equipment damage!

Содержание GB2S-STDO

Страница 1: ...able if you need to contact your local dealer or AMKUS Rescue Systems EN13204 Designation MTO DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of ...

Страница 2: ... Z535 6 the definitions of the four signal words are as follows DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury...

Страница 3: ...and CHEMTREC com 3 0 SAFETY It is the responsibility of the user to insure that appropriate protective clothing and equipment are used to provide protection from those hazards to which personnel are exposed or could be exposed while working with this product CAUTION Always wear appropriate apparel AMKUS equipment is manufactured with superior craftsmanship and quality that is backed by a factory w...

Страница 4: ...ould be between 10 000 psi and 11 000 psi If you have a reading outside of that range contact your local dealer or AMKUS Inc DO NOT ATTEMPT TO ADJUST THE PRESSURE RELIEF SETTING 5 2 ROUTINE MAINTENANCE FOR HOSES After each use wipe clean hydraulic hoses with a light cleaning solvent such as Simple Green Inspect hydraulic hoses for damage to the outer rubber cover Damage exposing the wire braided r...

Страница 5: ...his power unit may be supplied either with hydraulic hoses attached pump hoses or with couplings that require extension hoses If your unit is equipped with couplings attach the extension hoses to the couplings on the power unit In either case connect the male and female couplings on each of the hydraulic hose line sets creating a loop 6 Follow the operating instructions in the engine owner s manua...

Страница 6: ...g the knob on the corresponding selector valve to the pressure position in line with the hose line to which the tool is connected The selected tool is now operational To stop the flow of hydraulic fluid to each hose line move the knob of the corresponding selector valve to the neutral position perpendicular to the hose line The selector valve should be in the neutral position when you are finished...

Страница 7: ...c for further guidance PROBLEM SOLUTION Engine will not start or poor engine performance Check owner s manual troubleshooting guide Rescue tool lacks power or speed Check hydraulic fluid level in power unit reservoir Fluid leaks at fittings or hoses Check tightness of hose fittings Replace damaged hoses Tools do not operate Check to see that the power unit is running Check to see that the line is ...

Страница 8: ...ol markings are legible Contact your local dealer or AMKUS Rescue Systems for replacement labels 2 Wipe tool hoses fittings and couplings clean see routine maintenance for hoses and couplings 3 Inspect the poser unit hoses fittings and couplings after each use for damage leakage and excessive wear 4 If damage or excessive wear is noticed do not use the power unit contact your local dealer or AMKUS...