8. Indications and settings
8.1. System LEDs
Fig. 9 - Front panel LEDs detail (System LEDs)
LED
Color
PW
Yellow
RN
Green
S0
Red
S1
Green
LED
Status
Meaning
PWR
Lights
Power supply voltage indication
RN
Blinks, T = 2 s
Operation state
Blinks, T = 200 ms
Service mode
S1
Blinks
FW update is running
S0
Blinks
Error status
Application program is loaded to analyser, the device works faultlessly.
Analyser goes to Error state in following cases:
WTB configuration is missing or can not be read
Invalid Ethernet configuration
Application start failed
Occurrence of another error in operation
Follow the Programming manual to remove the failures.
Analyser is in this state in following cases:
from factory, until an application is loaded,
after intervention of ADS Manager program,
after pressing the RSTR button while gateway is switched on
In service mode is possible to load an application through ADS Manager
program.
LED colors
Meaning of
LED
Operation
state
Error status
Service mode