APT4015A(
X
)
apt4015ax_g_en_100
8/49
Quantity
1
Operation indication
No
Galvanic isolation
No
Recommended cabling
Shielded cable
Logical level 0 (input)
-30 V to +0.6 V
Logical level 1 (input)
+2.4 V to +30 V
Connection point
D-sub DE-9 plug,
connector fixing by UNC4-40 thread bolt
Quantity
2
6
)
Operation indication
LED (LNK and ACT)
Galvanic isolation
Yes
Insulation strength
1000 V AC /1 minute
7
)
Transmission speed
1 Gbps
Connection point
Connector RJ45, according to IEEE802.3
6
) When using TouchDet (see chapter 9.2
“APT4015AT – TouchDet”), the
user may only configure 1 IP address. Interfaces works as a switch.
7
) Insulation must not be used for separation of dangerous voltages
Quantity
2
Type
USB 2.0 type A
Operation indication
No
Galvanic isolation
No
Transmission speed
12 Mbps / 480 Mbps
Recommended cabling
Shielded USB cable
Connection point
2× USB connector, type A
Rated supply voltages
24 V DC
Supply voltage range
16.8 V DC to 33.6 V DC
Maximum power consumption
1 A at 24 V DC
1.3 A at 16.8 V DC
Power dissipation (typical)
12 W
Starting peak current
430 A / < 10 µs
Galvanic isolation
No
Connection point
WAGO 231-302/102-000
Wire cross-section
0.75 mm
2
to 2.5 mm
2
Power supply
The device must not be powered from the DC
distribution network of the building
8
)
8
) For more details, see chapter 8.3
“Installation principles”, paragraph “Power
supply”.
Mechanical design
Duralumin panel, metal cover
Colour
– front panel
– rear cover
Black RAL 9005, fine matte
Black RAL 9005, soft matte
Assembly
Into switchboard front panel
Ingress protection rate
Front panel IP54
9
)
Rear cover IP20
Weight
– netto
– brutto
4.00 kg ±5 %
5.00 kg ±5 %
Dimensions (w x h x d)
(420 × 254 × 66) mm
Package dimensions (w × h × d)
(480 × 340 × 135) mm
9
) Follow the assembly instructions, see chapter 8.1
“Assembly instructions”.
RS232
Ethernet
Note
USB
Power supply
Note
Mechanics
Note