KS-111E
ks-111e_g_en_100
48/52
Fig. 54 - Legend to camera body
3. Press and hold the
Control button
, attach the network cable.
4. Hold the
Control button
and wait until LED Status indicator starts light
yellow (it can take up to 15 seconds).
5. Release the
Control button
. When the LED Status indicator starts light
green (it can take up to 1 minute), process is completed an camera is re-
seted.
6. Perform the camera configuration according to 4.2 Cameras commission-
ing.
11.2. Meaning of camera LED indicators
LED
Color
Description
NET
Green
Connected to 100 Mbit/s network. Blinking indicates the net-
work activity.
Orange
Connected to 10 Mbit/s network. Blinking indicates the network
activity.
Does not
light
Not connected to network.
STAT
Green
Camera runs and is OK.
Orange
Camera start / reset to factory setting is under way.
Red
Blinks slowly after unsuccessful firmware upgrade.
PWM
Green
Power supply is attached.
Orange
Blinks green/orange when firmware upgrade is under way.
Does not
light
Camera is not powered.
Содержание AIPM1010/A